Requirements for the operation of the Meta-detector are given in the table:

Camera
  • Resolution must be at least 640x360. We also don't recommend using a resolution higher than 640х360, since higher resolution doesn't increase the detection quality, but significantly increases the consumption of resources. The optimal resolution for solving typical tasks is 640х360
  • The frame rate per second in the video stream from the camera is at least 2 for solving typical tasks

Attention!

  • Correct operation of the detector isn't guaranteed if you use frames that were masked before they got into Axxon One by an IP camera or similar methods.
  • Correct operation of the detector isn't guaranteed when you use a fisheye lens.
Lighting
  • Lighting in the scene is at least 50 lux. In conditions of insufficient or excessive lighting (night or light-striking), stable operation of the analytics isn't guaranteed
  • No abrupt changes in lighting
Scene and camera angle
  • Moving objects are visually separable from each other
  • The background is mostly static and doesn't change abruptly
  • Moving objects are minimally obscured by static objects in the scene (columns, industrial products, and so on)
  • The analyzed scene doesn't have reflective surfaces or sharp shadows from moving objects. If present, they must be masked
  • Camera shake doesn't result in image offsets greater than 1% of the frame size
  • No labels