Settings panel of the Monitoring interface object is given on figure.
Description of the Monitoring object settings panel elements is given in table.
# | Name | Method for setting the parameter value | Description | Type | Default value | Value range |
---|---|---|---|---|---|---|
1 | Identifier | Automatically | Shows the identification number of the Monitoring object in the system | Nonnegative integer | - | >=0 |
2 | Name | Enter the value in the field | Shows the name of the Monitoring object in the system | Latin, Cyrillic letters and service characters | Monitoring | A line representing a sequence of any symbols (letters, digits, service characters apart from > and < symbols), not case-sensitive. |
3 | Display | Is selected in the list | Assigns the parent Display object for the Monitoring object | Names of Display objects registered in the system | Name of the parent Display object | Depends on the number of the Display objects in the system. |
4 | Owners panel | Is set in a checkbox | Enables Owners panel displaying | Boolean | True | True - Owners panel is displayed False - Owners panel is hidden |
5 | X: | Enter the value in the field | Set the X coordinate in the horizontal axis for the upper-left corner of the Owners panel interface box | % of the screen width | 0 | from 0 to 100. When more than one monitor is connected to the computer it is possible to use coordinates outside this range, but it is not recommended to use coordinates less than -200. |
6 | Y: | Enter the value in the field | Set the Y coordinate in the vertical axis for the upper-left corner of the Owners panel interface box | % of the screen width | 50 | from 0 to 100. When more than one monitor is connected to the computer it is possible to use coordinates outside this range, but it is not recommended to use coordinates less than -200. |
7 | W: | Enter the value in the field | Set the width of the Owners panel interface box | % of the screen width | 100 | from 0 to 100. When more than one monitor is connected to the computer it is possible to use coordinates outside this range, but it is not recommended to use coordinates less than -200. |
8 | H: | Enter the value in the field | Set the height of the Owners panel interface box | % of the screen width | 50 | from 0 to 100. When more than one monitor is connected to the computer it is possible to use coordinates outside this range, but it is not recommended to use coordinates less than -200. |
9 | Control panel | Is set in a checkbox | Enables Control panel displaying | Boolean | True | True - Control panel is displayed |
10 | X: | Enter the value in the field | Set the X coordinate in the horizontal axis for the upper-left corner of the Control panel interface box | % of the screen width | 0 | from 0 to 100. When more than one monitor is connected to the computer it is possible to use coordinates outside this range, but it is not recommended to use coordinates less than -200. |
11 | Y: | Enter the value in the field | Set the Y coordinate in the vertical axis for the upper-left corner of the Control panel interface box | % of the screen height | 50 | from 0 to 100. When more than one monitor is connected to the computer it is possible to use coordinates outside this range, but it is not recommended to use coordinates less than -200. |
12 | W: | Enter the value in the field | Set the width of the Control panel interface box | % of the screen width | 100 | from 0 to 100. When more than one monitor is connected to the computer it is possible to use coordinates outside this range, but it is not recommended to use coordinates less than -200. |
13 | H: | Enter the value in the field | Set the height of the Control panel interface box | % of the screen height | 50 | from 0 to 100. When more than one monitor is connected to the computer it is possible to use coordinates outside this range, but it is not recommended to use coordinates less than -200. |
14 | Log panel | Is set in a checkbox | Enables Log panel displaying | Boolean | True | True - Log panel is displayed |
15 | X: | Enter the value in the field | Set the X coordinate in the horizontal axis for the upper-left corner of the Log panel interface box | % of the screen width | 0 | from 0 to 100. When more than one monitor is connected to the computer it is possible to use coordinates outside this range, but it is not recommended to use coordinates less than -200. |
16 | Y: | Enter the value in the field | Set the Y coordinate in the vertical axis for the upper-left corner of the Log panel interface box | % of the screen height | 0 | from 0 to 100. When more than one monitor is connected to the computer it is possible to use coordinates outside this range, but it is not recommended to use coordinates less than -200. |
17 | W: | Enter the value in the field | Set the width of the Log panel interface box | % of the screen width | 100 | from 0 to 100. When more than one monitor is connected to the computer it is possible to use coordinates outside this range, but it is not recommended to use coordinates less than -200. |
18 | H: | Enter the value in the field | Set the height of the Log panel interface box | % of the screen width | 50 | from 0 to 100. When more than one monitor is connected to the computer it is possible to use coordinates outside this range, but it is not recommended to use coordinates less than -200. |
19 | Non-empty Comment field | Is set in a checkbox | Is set to require that operators leave comments when accepting an alarm to describe the alarm and/or their actions | Boolean | True | True - Comment field shall not be empty on alarm accepting |
20 | Use filter by events | Is set in a checkbox | Is set to enable filtering objects by Alarm and Failure events and Connected and Disconnected states. | Boolean | True | True – filter can be applied. False – filter cannot be applied. |
21 | Warning when watching live video | Is set in a checkbox | Is set if it is necessary to display a warning upon the live video playback attempt that it can create the critical load on the data channel | Boolean | True | True - when live video is attempted to be viewed, the warning is displayed |
22 | Viewing live video through gateway | Is set in a checkbox | Is set if Agents of Control and Additional workplaces are in different subnets and the Monitoring components are not in a distributed system configuration in Intellect object tree and Data gateway is in use for transmission of live video to Additional workplaces | Boolean | False | True – live video is transferred to the Additional workplaces through the data gateway. False – live video is transferred to the Additional workplaces directly from the Agent of Control. |
23 | Viewing live video from all cameras (add.) | Is set in a checkbox | Is set if the "All cameras of Partition of Control" item should be added to the object's "Video image playback" context menu which enables viewing video from all cameras of the selected Partition of Control. | Boolean | False | True – the "All cameras of Partition of Control" item is added to the object's "Video image playback" context menu. False – there is no "All cameras of Partition of Control" item in the menu. |
24 | Video stream speed | Enter the value in the field | Sets the number of frames per second of the video image when viewing live video or video from the archive.
| Frames per second | 25 | Depends on the camera features |
25 | Compression | Select from the list | Sets live video compression rate | Supported compression rates | No | 0-5 |
26 | Groups of alarms | Is set in a checkbox | Sets alarms that one want to visualize on the Control panel | Boolean | All checkboxes except the Temperature sensors are set | If checkbox is set next to the group of alarms, then alarm from the corresponding group will be displayed on the Control panel |
27 | Filter by owners | Via the Filters... button | Displays selected pairs of users and owners | - | - | - |
28 | Filter... | Click the button | Opens a dialog box to match owners to users | - | - | - |