Settings panel of the Partition of Control object is given on figure.
Description of the Partition of Control object settings panel elements is given in table.
# | Name | Method for setting the parameter value | Description | Type | Default value | Value range |
---|---|---|---|---|---|---|
1 | Identifier | Automatically | Shows the identification number of the Partition of Control object in the system | Nonnegative integer | - | Depends on number of Partition of Control objects in the system |
2 | Name | Enter the value in the field | Shows the name of the Partition of Control object in the system | Latin, Cyrillic letters and service characters | Partition of Control | A line representing a sequence of any symbols (letters, digits, service characters apart from > and < symbols), not case-sensitive. |
3 | Agent of Control | Is selected in the list | Assigns the parent Agent of Control object for the Partition of Control object | Names of Agent of Control objects registered in the system | Name of the parent Agent of Control object | Depends on the number of the Agent of Control objects in the system. |
4 | ID | Enter the value in the field | Sets the unique ID number for the object where Agent of Control is installed | Latin, Cyrillic letters and service characters | 386 | A line representing a sequence of any symbols (letters, digits, service characters excluding characters: space "", underscore "_" and backslash "\"), not case-sensitive. |
5 | TCP port (UPS) | Enter the value in the field | Sets the port on which to "listen" for UPS messages | Nonnegative integer | 8888 | from 1 to 60000 |
6 | Transmitting... | Click the button | Opens a dialog box with settings for configuring the communication method between Agent of Control and Server of Control | - | - | - |
7 | Monitoring... | Click the button | Opens a dialog box for configuring alarm groups | - | - | - |
8 | Video data... | Click the button | Opens a dialog box for setting video data transferring configurations | - | - | - |
9 | Cameras | Using the Cameras... button | Displays the list of cameras whose state and archives are monitored by Agent of Control and operating with which shall be available from Monitoring software interface. | - | - | - |
10 | Cameras... | Click the button | Opens a dialog box for adding cameras for monitoring | - | - | - |
11 | Sensors | Using the Add, Edit and Delete buttons | Displays IDs and types of sensors whose state is monitored by Agent of Control and on whose triggering video data are sent to the Server of Control. | - | - | - |
12 | Temperature sensor set | Is set in a checkbox | Specifies if monitoring to ensure that temperatures do not deviate from an allowed range is performed using temperature sensors | Boolean | False | True – temperature sensors set is in use |
13 | Add... | Click the button | Opens a dialog box for adding a sensor. In this dialog box one can also setup video data sending on the sensor triggering | - | - | - |
14 | Edit... | Click the button | Opens a dialog box for editing the sensor. This dialog box is similar to the one for adding a sensor | - | - | - |
15 | Delete | Click the button | Deletes sensor from the list | - | - | - |