Settings panel of the Search in archive interface object is given on figure.

Description of the Search in archive object settings panel elements is given in table.
 

#

Name

Method for setting the parameter value

Description

Type

Default value

Value range

1

Identifier

Automatically

Shows the identification number of the Search in archive object in the system

Nonnegative integer

-

>=0

2

Name

Enter the value in the field

Shows the name of the Search in archive object in the system

Latin, Cyrillic letters and service characters

Monitoring

A line representing a sequence of any symbols (letters, digits, service characters apart from > and < symbols), not case-sensitive.
Number of symbols – from 1 to 60.

3

Display

Is selected in the list

Assigns the parent Display object for the Search in archive object

Names of Display objects registered in the system

Name of the parent Display object

Depends on the number of the Display objects in the system.

4

X:

Enter the value in the field

Set the X coordinate in the horizontal axis for the upper-left corner of the Search in archive interface box

% of the screen width

0

from 0 to 100. When more than one monitor is connected to the computer it is possible to use coordinates outside this range, but it is not recommended to use coordinates less than -200.

5

Y:

Enter the value in the field

Set the Y coordinate in the vertical axis for the upper-left corner of the Search in archive interface box

% of the screen height

50

from 0 to 100. When more than one monitor is connected to the computer it is possible to use coordinates outside this range, but it is not recommended to use coordinates less than -200.

6

W:

Enter the value in the field

Sets width of he Search in archive interface box

% of the screen width

100

from 0 to 100. When more than one monitor is connected to the computer it is possible to use coordinates outside this range, but it is not recommended to use coordinates less than -200.

7

H:

Enter the value in the field

Sets height of he Search in archive interface box

% of the screen height

50

from 0 to 100. When more than one monitor is connected to the computer it is possible to use coordinates outside this range, but it is not recommended to use coordinates less than -200.

8Filter by ownersVia the Filter... buttonDisplays selected pairs of users and owners---
9Filter...Click the buttonOpens a dialog box to match owners to users---