General information
The status bar displays:
- CC - the start of the displayed period for the current cell column.
- LL - the time when the data was last loaded into the database.
- OB - the total number of "not ignored" objects.
- FO - the number of objects with hardware problems displayed at a given time.
- Cam - the camera statistics: total number of cameras at the facilities/number of working cameras/number of faulty cameras.
- IF% - the video surveillance system functioning rate.
- IN% - the video surveillance system non-functioning rate by reasons.
You can hover the mouse cursor directly over the status bar to display a tooltip.
Attention!
If filtering is enabled, then in order to calculate rates (IF% and IN%) and camera statistics (Cam) only for filtered objects, click (Calculate rates and cameras only for filtered table lines).
Functioning and non-functioning rates
Note
Functioning (IF%) and non-functioning (IN%) rates are calculated only for “not ignored” objects. For “ignored” objects, rates are not calculated and the filter is never used (see Ignоring objects). Zero values of non-functioning rates are not shown on the status bar.
Rates (IF% and IN%) are not calculated if Alarms, Failures or Disconnected filter is enabled (see Number of alarms displayed).
Functioning rate (IF%) is calculated according to the following formula:
(1-Nnf/Na)*100, where
- Nnf is the number of objects that do not function properly.
- Na is the total number of objects
The non-functioning rate (IN%) for a particular reason is calculated according to the following formula:
(Nnfbr/Na)*100, where
- Nnfbr is the number of objects that do not function properly for this particular reason