Go to documentation repository
Documentation for Monitoring 13.0. Documentation for other versions of Monitoring is available too.
To accept several alarms, or all alarms of an object, or all alarms of all objects, simultaneously, do the following:
- Click the icon that is informing about the alarm. The Reaction to alarm window opens.
- To accept several similar alarms, proceed as follows:
- Select several alarms from the list in one of the following ways:
- Use the left mouse button and the Ctrl or Shift key.
- Right-click on the list and click Select all item in the menu.
- Fill in the Comment field if necessary.
- Click Confirm selected.
- Select several alarms from the list in one of the following ways:
- To accept all alarms of an object, click Confirm. A dialog box displays to confirm the action. Click OK.
- To accept all alarms of all objects, click Confirm all. A dialog box displays to confirm the action. Click OK.
Note.
If a comment is required but the Comment field is empty, the Confirm selected, Confirm and Confirm all buttons are inactive.
Multiple alarms are now confirmed.
If a simple confirmation of alarm acceptance is configured, then only one confirmation is sent to the Agent of Control when a group of similar alarms is accepted on the Server of Control. If there should be a complex confirmation, then several alarms of the same type cannot be accepted. Each alarm is to be processed individually.
If all alarms of one or all objects are confirmed, simple or complex confirmation settings are ignored and no confirmation is sent to the Agent of Control.