# | Name | Method for setting the parameter value | Description | Type | Default value | Value range |
---|---|---|---|---|---|---|
1 | Identifier | Automatically | Shows the identification number of the Server of Control object in the system | Nonnegative integer | - | >=0 |
2 | Name | Enter the value in the field | Shows the name of the Server of Control object in the system | Latin, Cyrillic letters and service characters | Server of Control | A line representing a sequence of any symbols (letters, digits, service characters apart from > and < symbols), not case-sensitive. |
3 | Computer | Is selected in the list | Assigns the parent Computer object for the Server of Control object | Name of the Computer objects registered in the system. | Name of the parent Computer object | Depends on the number of the Computer objects in the system. |
4 | IIDK interface | Enter a value in the field | Sets the ID of the IIDK interface object used by the Server of Control | Nonnegative integer | 150 | >=0 |
5 | Event Viewer | Click the button | Opens the Event Viewer tool | - | - | - |
Advanced group | ||||||
6 | Monitoring… | Click the button | Opens the box of setting the list of additional workplaces | |||
7 | Snapshots/video... | Click the button | Opens a dialog box for configuring reaction to snapshots and videos receiving on sensors alarms at the Agent of Control | - | - | - |
Logging subsystem group | ||||||
8 | Auxiliary characters | Is set in a checkbox | Enables logging of auxiliary characters at the transport level into the event log | Boolean | False | True – logging of auxiliary characters is enabled |
9 | Alarms | Is set in a checkbox | Enables logging alarms into the event log | Boolean | True | True – logging of alarms is enabled |
10 | System status | Is set in a checkbox | Enables logging of events related to system status | Boolean | True | True – logging of events related to system status is enabled |
11 | Archive period (h) | Enter the value in the field | Sets the frequency at which the log file is to be archived | Hours | 48 | >0 |
12 | File size (MB) | Enter the value in the field | Sets the file size threshold upon which the log file is archived. This setting overrides the value in the Archive period (h) field. | Megabytes | 100 | >0 |
13 | Keep archives for (months) | Enter the value in the field | Sets the length of time for which you want to store archived log files. | Months | 3 | from 1 to 24 |
Transfer group | ||||||
14 | TCP/IP port (Agent) | Enter the value in the field | Sets the port number for TCP/IP communication with remote objects of Agent of Control | Nonnegative integer | 7777 | from 1 to 60000 |
15 | TCP/IP port (Archive) | Enter the value in the field | Sets the port number for TCP/IP communication with remote Search in archive module | Nonnegative integer | 7755 | from 1 to 60000 |
16 | First COM port number | Is selected in the list | Sets the first COM port number | COM-ports names | Com1 | from Com1 to Com256 |
17 | Number of COM ports | Is selected in the list | Sets number of COM ports used | Nonnegative integer | 1 | from 1 to 256 |
18 | COM port speed | Is selected in the list | Sets the COM port speed | Baud | 9600 | 110 |
19 | COM port format | Enter the value in the field | Sets the COM port format | COM port format | 8N1 |
|
Outside the groups | ||||||
20 | Transfer info about accepted alarms to Agent of Control | Set the checkbox | Enables sending confirmations of alarm acceptance by the operator on the Server of Control to the Agent of Control. | Boolean type | Yes | True – confirmations of alarm acceptance are sent. False – confirmations of alarm acceptance are not sent |
21 | Restart | Click the button | VideoSrv communication module restarting | - | - | - |