Documentation for Monitoring 14.0. Documentation for other versions of Monitoring is available too.

Previous page Configuring sound notification at Server of Control  Configuring sound notification at Server Of Control for various alarm groups Next page

Monitoring allows configuring audio signal that accompanies alarm messages received from Agents Of Control. For this, do the following:

Note

This function is not supported for the Additional Workstation in non-distributed configuration.
  1. Create a Display object in the Interfaces tab.
  2. Create an Audio player object on the basis of the Display object.
  3. Run the System configuration utility (ddi.exe).

    Note

    Detailed information on using this utility is given in the Intellect software. Administrator's Guide. The most relevant version of this document is available in AxxonSoft documentation repository.
  4. Open the intellect.atm.ddi file.
  5. Select the VIDEOSRV_S_DVC (Partition Of control) object.
  6. Go to the Events tab.
  7. In the Audio support column, set the checkboxes next to all events that have to be accompanied by an audio signal.
    A tooltip shows the required name of the WAV file.
    N is an ID of the VIDEOSRV_S_DVC_ATM object.
  8. Create corresponding files and place them into the <Intellect installation>\Wav folder.

Configuration of sound notification at Server Of Control is completed.

  • No labels