Documentation for Monitoring 10.0. Documentation for other versions of Monitoring is available too.

Previous page Features of displaying information on short-term and long-term alarms  Release Notes Next page

Agent of Control technical condition data collection periods are given below:

  1. Information on disk failures (the Disk failure alarm type) and its restoring is updated in the following cases:
    1. at Agent of Control startup and then every 15 minutes.
    2. at receiving local message SLAVE|NO_DISC (No disk for archive storage) from Intellect core.
    3. at receiving local message DISC_EXIST (Disk for archive storage found) from Intellect core.
    4. at receiving local message DISC_UNMOUNT (Disk unmounted) from Intellect core.
    5. at receiving local message DISC_MOUNT (Disk mounted) from Intellect core.
  2. Information on archive size (the Small archive size alarm type) is updated at Agent of Control startup and then every 15 minutes.
  3. Information on the computer normal and abnormal restarts is displayed in the interface within 5 minutes.
  4. Information on free disk space is updated every 1 hour.
  5. Agent of Control initiates the connection with Server of Control and once in a ping period (2 minutes by default) sends a package with technical data to the Server of Control. If Server of Control haven't been receiving any data from Agent of Control for 6 minutes, the "No connection" error is displayed for such object.

    Note

    The waiting timeout for receiving the packets with the technical state of Agent of Control can be adjusted. To do this, it is necessary to perform the following actions on the Server of Control side:

    1. For the Partitions of Control, which waiting timeout should be adjusted, specifiy the prefix in the identifier.
    2. For the PrefixForTimeOut registry key, set the value equal to the previously specified prefix.
    3. For the TimeoutForPrefix registry key, set the timeout value in minutes.
    4. For the UsingTimeoutForPrefix registry key, set the 1 value to enable the waiting timeout.
    5. When changing the timeout, it is recommended to adjust the Server of Control polling period on the Agent of Control side (see Configuring communication between Agent of Control and Server of Control).

    For details, see Registry keys reference guide, for more information about working with the registry, see Working with Windows OS registry.

  6. The Video.run process status (hangup) is checked at startup of Videosrv.exe module and then every 15 minutes, and besides that each time the Videosrv.exe module reconnects with the Intellect software, i.e. if the Intellect software was shut down and started again. 
  7. Availability of running processes "Intellect.exe" and "Video.run" is checked every 10 seconds.