Go to documentation repository
Page History
...
Go to the Synchronization parameter group on the settings panel of the Castle server object.
Set the Use auto synchronization checkbox to automatically synchronize parameters between Intellect Server and rewrite all access parameters to Castle Server with a specified interval (1).
Note The Use auto synchronization checkbox is always to be checked for proper operation of Castle integration moduletitle Attention! The synchronization is only performed if a change occured in users' parameters between synchronization intervals. If there were no changes, the configuration is not rewritten.
In the Synchronization interval, h field, set the period (in hours) of parameters synchronization (2).
To read Castle ACS access points configuration stored on Castle server click the Hardware synchronization button (3).
To send ACFA Intellect configuration to Castle server click the Save configuration button (4).
Note title Attention! This action is to be performed after configuring interaction between Intellect and Castle servers.
Set the Dynamic sending checkbox to enable constant connection between Intellect and Castle servers (5).
Note title Attention! The Dynamic sending checkbox is always to be checked for proper operation of Castle integration module. If it is not, use Save configuration or Send AM data to controllers every time you change hardware or user parameters correspondingly.
Click Send AM data to controllers to send configuration of ACFA Intellect users to Castle controllers (6).
Set the Transmit command to record to controllers checkbox to enable automatic sending of ACFA Intellect users configuration to controllers after clicking Save configuration (7).
Info title Note. If the Transmit command to record to controllers checkbox is not set, click Send AM data to controllers (6) every time after clicking Save configuration (4).
- Click the Apply button.
...