The controller C3-100 is configured on the settings panel of the AC ZK Controller C3-100 object which is created on the basis of the AC ZK Teco object on the Hardware tab of the System settings dialog window.

To configure the C3-100 controller, do the following:

  1. Go to the settings panel of the AC ZK Controller C3-100 object.
  2. From the Gate: drop-down list select the type of controller connection: via Ethernet or RS-485 standard (1).
  3. In the Password: field enter the password for controller connection (2).
  4. In the IP: field enter the IP-address of the controller (3).
  5. From the Anti-passback: drop-down list select the mode of anti-passback operation (4):

    Mode

    Description

    Controller

    Disable

    The anti-passback function is disabledAll controllers
    Readers of Door 1The anti-passback function is enabled between the readers of Door 1ZK C3-100, ZK C3-200
    Readers of Door 2The anti-passback function is enabled between the readers of Door 2ZK C3-200
    Readers of door 1, readers of door 2The anti-passback function is enabled between the readers of Door 1 and Door 2 respectivelyZK C3-200
    Door 1 and 2The anti-passback function is enabled between the readers of Door 1 and Door 2ZK C3-200, ZK C3-400
    Doors 3 and 4The anti-passback function is enabled between the readers of Door 3 and Door 4ZK C3-400
    Doors 1 and 2, doors 3 and 4The anti-passback function is enabled between the readers of Door 1, Door 2, Door 3 and Door 4ZK C3-400

    Doors 1, 2 and doors 3, 4

    The anti-passback is enabled between Door 1, 2 and Door 3, 4ZK C3-400
    Door 1 and doors 2, 3The anti-passback is enabled between Door 1 and Door 2, 3ZK C3-400
    Door 1 and doors 2, 3, 4 The anti-passback is enabled between Door 1 and Door 2, 3, 4ZK C3-400


  6. From the Interlock: drop-down list select the mode of doors interlocking (5):

    Mode

    Description

    Controller

    Disable

    The interlock function is disabledAll controllers
    Door 1 and 2Doors 1 and 2 are interlocked mutuallyZK C3-200, ZK C3-400
    Door 3 and 4Door 3 and door 4 are interlocked mutuallyZK C3-400
    Doors 1, 2 and 4Door 1, door 2 and door 4 are interlocked mutuallyZK C3-400

    Doors 1 and 2, doors 3 and 4

    Door 1 and door 2 are interlocked mutually, door 3 and door 4 are interlocked mutuallyZK C3-400
    Doors 1, 2, 3 and 4Door 1, door 2, door 3 and door 4 are interlocked mutuallyZK C3-400


  7. From the Backup period: drop-down list select the time interval in minutes for saving the database backup (6).
  8. Set the Watch dog checkbox to activate the control mode (7).

    Info
    titleNote.

    The version of firmware and serial number of controller will automatically display in the corresponding fields while connecting the controller (8).


  9. Click the Apply button (9).

Configuring of the C3-100 controller is completed.