The settings panel of the SIP-device object is shown in the pictures below.

Parameter

Method for setting the parameter value

Description

Presented as

Default value

Range of values

The Connection settings group

1The User ID fieldEnter the value in the fieldSets the SIP-device identification number, i.e. the number to call it.Integer
>=0
2The IP address fieldEnter the value in the field

For SIP-server terminal type only

Sets the SIP-device IP address.

IP address
1.0.0.0 - 255.255.255.255
3The Password fieldEnter the value in the field

For SIP-server terminal type only

Sets the password specified on the SIP-device.

Latin, Cyrillic letters and service characters
A line representing a sequence of any symbols
4The State fieldAutomatically

For SIP-server terminal type only

Displays the SIP device state

---
5The Device type drop-down listIs selected in the listSets the icon type to represent the device on the Map.Names of the available icon types-

SIP client — the SIP-device acts as a client, it can be connected to any SIP-server

SIP server — the SIP-device acts as a server, any SIP-clients can be connected to it

Peer-to-peer terminal type is not supported at the present moment.

6The Device priority drop-down listIs selected in the listSets the device calls priority when displayed on the SIP panelInteger-

0 – 10

The higher the number the higher the priority.

If the field left empty, the priority is considered minimal. 

Table describes the parameters of the SIP-device settings panel.

...

Table describes the parameters of the SIP-device settings panel.

Parameter

Method for setting the parameter value

Description

Presented as

Default value

Range of values

1The DTMF type drop-down listIs selected in the listSets the type of the tone DTMF commandSupported signal typein_bound

in_

band –

band – the signal is transmitted as normal sound in an audio stream.

rtp

http_

nte –

bassignals are transmitted

via RTP

over the HTTP protocol separately from the voice stream.

sip_

info –

info – signals are transmitted in the SIP INFO message.

sip_

notify –

notify – signals are transmitted in the SIP NOTIFY message.

2The Signal duration, ms fieldEnter the value in the fieldSets the time period in milliseconds during which the command is to be sent.Integer
>0
The Device connection settings group
3The Login field Enter the value in the fieldSets the user name to connect to the (BasIP) SIP deviceLatin, Cyrillic letters and service characters-A line representing a sequence of any symbols
The Password field Enter the value in the fieldSets the password to connect to the (BasIP) SIP deviceLatin, Cyrillic letters and service characters-A line representing a sequence of any symbols
The IP address field Enter the value in the fieldSets the (BasIP) SIP device IP addressIP address-1.0.0.0 - 255.255.255.255
4The Name fieldEnter the value in the fieldSets the name of the command displayed on the SIP panel Latin, Cyrillic letters and service characters
A line representing a sequence of any symbols
3
5The Code fieldEnter the value in the fieldSets the unique command codeInteger or HTTP request (for http_bas)
>0