Go to documentation repository
Page History
The settings panel of the SIP-device object is shown in the pictures below.
№ | Parameter | Method for setting the parameter value | Description | Presented as | Default value | Range of values |
The Connection settings group | ||||||
1 | The User ID field | Enter the value in the field | Sets the SIP-device identification number, i.e. the number to call it. | Integer | >=0 | |
2 | The IP address field | Enter the value in the field | For SIP-server terminal type only Sets the SIP-device IP address. | IP address | 1.0.0.0 - 255.255.255.255 | |
3 | The Password field | Enter the value in the field | For SIP-server terminal type only Sets the password specified on the SIP-device. | Latin, Cyrillic letters and service characters | A line representing a sequence of any symbols | |
4 | The State field | Automatically | For SIP-server terminal type only Displays the SIP device state | - | - | - |
5 | The Device type drop-down list | Is selected in the list | Sets the icon type to represent the device on the Map. | Names of the available icon types | - | SIP client — the SIP-device acts as a client, it can be connected to any SIP-server SIP server — the SIP-device acts as a server, any SIP-clients can be connected to it Peer-to-peer terminal type is not supported at the present moment. |
6 | The Device priority drop-down list | Is selected in the list | Sets the device calls priority when displayed on the SIP panel | Integer | - | 0 – 10 The higher the number the higher the priority. If the field left empty, the priority is considered minimal. |
Table describes the parameters of the SIP-device settings panel.
...
Table describes the parameters of the SIP-device settings panel.
№ | Parameter | Method for setting the parameter value | Description | Presented as | Default value | Range of values |
1 | The DTMF type drop-down list | Is selected in the list | Sets the type of the tone DTMF command | Supported signal type | in_bound | in_ |
band – the signal is transmitted as normal sound in an audio stream. |
http_ |
bas – signals are transmitted |
over the HTTP protocol separately from the voice stream. sip_ |
info – signals are transmitted in the SIP INFO message. sip_ |
notify – signals are transmitted in the SIP NOTIFY message. | ||||||
2 | The Signal duration, ms field | Enter the value in the field | Sets the time period in milliseconds during which the command is to be sent. | Integer | >0 | |
The Device connection settings group | ||||||
3 | The Login field | Enter the value in the field | Sets the user name to connect to the (BasIP) SIP device | Latin, Cyrillic letters and service characters | - | A line representing a sequence of any symbols |
The Password field | Enter the value in the field | Sets the password to connect to the (BasIP) SIP device | Latin, Cyrillic letters and service characters | - | A line representing a sequence of any symbols | |
The IP address field | Enter the value in the field | Sets the (BasIP) SIP device IP address | IP address | - | 1.0.0.0 - 255.255.255.255 | |
4 | The Name field | Enter the value in the field | Sets the name of the command displayed on the SIP panel | Latin, Cyrillic letters and service characters | A line representing a sequence of any symbols |
5 | The Code field | Enter the value in the field | Sets the unique command code | Integer or HTTP request (for http_bas) | >0 |