Documentation for Intellect 4.11.0-4.11.3. Documentation for other versions of Intellect is available too.

Previous page Next page


You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 4 Next »

The settings panel of the SIP-device object is shown in the pictures below.

Parameter

Method for setting the parameter value

Description

Presented as

Default value

Range of values

The Connection settings group

1The User ID fieldEnter the value in the fieldSets the SIP-device identification number, i.e. the number to call it.Integer
>=0
2The IP address fieldEnter the value in the field

For SIP-server terminal type only

Sets the SIP-device IP address.

IP address
1.0.0.0 - 255.255.255.255
3The Password fieldEnter the value in the field

For SIP-server terminal type only

Sets the password specified on the SIP-device.

Latin, Cyrillic letters and service characters
A line representing a sequence of any symbols
4The State fieldAutomatically

For SIP-server terminal type only

Displays the SIP device state

---
5The Device type drop-down listIs selected in the listSets the icon type to represent the device on the Map.Names of the available icon types-

SIP client — the SIP-device acts as a client, it can be connected to any SIP-server

SIP server — the SIP-device acts as a server, any SIP-clients can be connected to it

Peer-to-peer terminal type is not supported at the present moment.

6The Device priority drop-down listIs selected in the listSets the device calls priority when displayed on the SIP panelInteger-

0 – 10

The higher the number the higher the priority.

If the field left empty, the priority is considered minimal. 

Table describes the parameters of the SIP-device settings panel.

Table describes the parameters of the SIP-device settings panel.

Parameter

Method for setting the parameter value

Description

Presented as

Default value

Range of values

The Video/Audio tab (for SIP-server terminal type only)
1The Video switchSet the switch to the required positionSets the video camera used for callsSupported options of camera usageOff

Off — the video is not used during the call.

SIP camera — a SIP-device camera connected via the SIP protocol is used.

Other — any other camera from the Intellect hardware tree selected from the Camera drop-down list is used.

2The Camera drop-down listIs selected in the listSets any video camera used for calls

Name of the Camera objects

registered in the system.

-Depends on the number of the Camers objects in the system.
3The Audio switchSet the switch to the required positionSets the microphone used for callsSupported options of audio usageOff

Off — the audio is not used during the call.

On — the microphone of the SIP-device is used.

4The Microphone fieldAutomaticallyDisplays the name of the Microphone object corresponding to the SIP device---

Table describes the parameters of the SIP-device settings panel.

Parameter

Method for setting the parameter value

Description

Presented as

Default value

Range of values

1The DTMF type drop-down listIs selected in the listSets the type of the tone DTMF commandSupported signal typein_bound

in_band – the signal is transmitted as normal sound in an audio stream.

rtp_nte – signals are transmitted via RTP separately from the voice stream.

sip_info – signals are transmitted in the SIP INFO message.

sip_notify – signals are transmitted in the SIP NOTIFY message.

2The Signal duration, ms fieldEnter the value in the fieldSets the time period in milliseconds during which the command is to be sent.Integer
>0
4The Name fieldEnter the value in the fieldSets the name of the command displayed on the SIP panel Latin, Cyrillic letters and service characters
A line representing a sequence of any symbols
3

















5The Code fieldEnter the value in the fieldSets the unique command codeInteger
>0
  • No labels