The settings panel of the SIP-operator object is shown in the pictures below.

Image Removed

Image Removed

Table describes the parameters of the SIP-operator settings panel system object.

Parameter

Method for setting the parameter value

Description

Presented as

Default value

Range of values

1

The

Identification number

Number field

Automatically

Shows

Sets the identification number

of theSIP-operator object in the system.

for calls

Sequence of numbers

-

Depends on the number of the SIP-operator objects in the system.

2

The Name field

Enter the value in the field

Assigns a name to the SIP-operator object in the system.

Latin, Cyrillic letters and service characters

SIP-operator

A line representing a sequence of any symbols

(letters, digits, service characters apart from > and < symbols), not case-sensitive.

Number of symbols – from 1 to 60.

3

The Disable checkbox

>=0

2The Bind operator to user rights checkbox
Is set with a checkbox
Shows the status (enabled or disabled) of the

Enables binding of a SIP-operator

object in the system.

Boolean type

-

Yes – the SIP-operator object is disabled and is not in use.

No – the SIP-operator object is enabled and is in use.

4

to Intellect user rights. Activates the User drop-down list.

Note. It is used when the User rights are selected by default on the operator's SIP panel.



Yes - binding of a SIP-operator to Intellect user rights is enabled

No - binding of a SIP-operator to Intellect user rights is disabled

3The User drop-down
The SIP-terminal dropdown
listIs selected in the list
Assigns the parent SIP-terminal object for the SIP-operator object
Sets the user under which it is necessary to register in Intellect.

Name of the

SIP-terminal

User objects

registered in the system.

Name of the parent

SIP-terminal object


Depends on the number of the
SIP-terminal
User objects in the system.
5The Ringing number fieldEnter the value in the fieldSets the operator identification numberInteger-

>=0

6
4The Device priority 
The User
drop-down listIs selected in the listSets
the corresponding Intellect user
the priority of a call from this operator in the incoming calls window of the SIP panel.Sequence of numbersNo

0 – 10

The lower the number, the higher the priority and, accordingly, the higher the display in the list.

If the field is left blank, then the priority is considered to be minimal.

Calls from operators with the same priority will be sorted by the time of the call.

The Server connection tab (only for SIP client terminal type)

Image Added

Table describes the parameters of the Server connection tab.

Parameter

Method for setting the parameter value

Description

Presented as

Default value

Range of values

1

Name of the User objects registered in the system.

Depends on the number of the User objects in the system.

The Server connection tab (for SIP-client terminal type only)

7
The Address fieldEnter the value in the fieldSets the IP address of the SIP-serverIP address-1.0.0.0 - 255.255.255.255
8
2The Port fieldEnter the value in the fieldSets the port of the SIP-serverInteger-0-65535
9
3The Login fieldEnter the value in the fieldSets the username for connecting to the SIP-serverLatin, Cyrillic letters and service characters-A line representing a sequence of any symbols (letters, numbers, service symbols)
10
4The Password fieldEnter the value in the fieldSets the password for connecting to the SIP-serverLatin, Cyrillic letters and service characters-A line representing a sequence of any symbols (letters, numbers, service symbols)

The Address book tab

Image Added

Table describes the parameters of the Address book tab.

Shows the numbers of devices, operators and special numbers

Parameter

Method for setting the parameter value

Description

Presented as

Default value

Range of values

1The Address books tableIs selected in the columnSets the list of address books, the numbers of which should be available for this SIP-operator--

-

The Number columnIs selected in the listSelecting the address book identifierIdentifiers of Address book objects registered in the system-Depends on the number of Address book objects in the system
The Name columnIs selected in the listSelecting the name of the address book in IntellectNames of Address book objects registered in the system-Depends on the number of Address book objects in the system
2The All buttonClick the buttonAdds all existing address books to the table
11The use columnSet the checkboxSets the devices, operators and special numbers that should be available in the SIP panel address book of this operator.Boolean typeNo

Yes – the number is displayed on the SIP panel

No – the number is not displayed on the SIP panel

12The Subscriber fieldAutomatically---
133The Name fieldAutomatically Range buttonClick the buttonOpens the Add address books window to add multiple address booksShows the names of devices, operators and special numbers---