The settings panel of the SIP-operator object is shown in the pictures below.
Table describes the parameters of the SIP-operator settings panel.
№ | Parameter | Method for setting the parameter value | Description | Presented as | Default value | Range of values |
1 | The Identification number field | Automatically | Shows the identification number of the SIP-operator object in the system. | Sequence of numbers | - | Depends on the number of the SIP-operator objects in the system. |
2 | The Name field | Enter the value in the field | Assigns a name to the SIP-operator object in the system. | Latin, Cyrillic letters and service characters | SIP-operator | A line representing a sequence of any symbols (letters, digits, service characters apart from > and < symbols), not case-sensitive. Number of symbols – from 1 to 60. |
3 | The Disable checkbox | Is set with a checkbox | Shows the status (enabled or disabled) of the SIP-operator object in the system. | Boolean type | - | Yes – the SIP-operator object is disabled and is not in use. No – the SIP-operator object is enabled and is in use. |
4 | The SIP-terminal dropdown list | Is selected in the list | Assigns the parent SIP-terminal object for the SIP-operator object. | Name of the SIP-terminal objects registered in the system. | Name of the parent SIP-terminal object | Depends on the number of the SIP-terminal objects in the system. |
5 | The Ringing number field | Enter the value in the field | Sets the operator identification number | Integer | - | >=0 |
6 | The User drop-down list | Is selected in the list | Sets the corresponding Intellect user | Name of the User objects registered in the system. | Depends on the number of the User objects in the system. | |
The Server connection tab (for SIP-client terminal type only) | ||||||
7 | The Address field | Enter the value in the field | Sets the IP address of the SIP-server | IP address | - | 1.0.0.0 - 255.255.255.255 |
8 | The Port field | Enter the value in the field | Sets the port of the SIP-server | Integer | - | 0-65535 |
9 | The Login field | Enter the value in the field | Sets the username for connecting to the SIP-server | Latin, Cyrillic letters and service characters | - | A line representing a sequence of any symbols |
10 | The Password field | Enter the value in the field | Sets the password for connecting to the SIP-server | Latin, Cyrillic letters and service characters | - | A line representing a sequence of any symbols |
The Address book tab | ||||||
11 | The use column | Set the checkbox | Sets the devices, operators and special numbers that should be available in the SIP panel address book of this operator. | Boolean type | No | Yes – the number is displayed on the SIP panel No – the number is not displayed on the SIP panel |
12 | The Subscriber field | Automatically | Shows the numbers of devices, operators and special numbers | - | - | - |
13 | The Name field | Automatically | Shows the names of devices, operators and special numbers | - | - | - |