- At the Server of Control and Agent of Control side:
- Create Audio card object with the Microphone object under it (see Audio subsystem configuration).
- Create Audio playback card object with the Speaker object under it (see Configuring audio playback).
- At the Server of Control side:
- Create a SIP-terminal object as a SIP server in Intellect (see Configuring SIP-terminal).
- On the basis of the SIP-terminal object, create 2 child SIP-operator objects and for each of them specify the corresponding operator identification number (Configuring SIP-operators of the Intellect's SIP server).
- On the basis of the SIP-terminal object, create the Address book object and select to use the previously created SIP operators (see Configuring address book of SIP-terminal).
- On the settings panel of each SIP-operator, select a previously created address book for use (see Configuring SIP-operators of the Intellect's SIP server).
- Create a SIP-panel 1 interface object on the same Screen 1 object where the Monitoring interface object was created (see Configuring the SIP-panel interface object).
Info title Note. Recommended coordinates of the SIP panel: X = 40, Y = 40, W = 20, H = 21. - On the Basic settings tab of the SIP panel 1 object, select the SIP terminal as the terminal (see Basic settings of the SIP-panel interface object).
- On the Advanced settings tab of the SIP panel 1 object, check the boxes as shown in the figure below (see Advanced settings of the SIP-panel interface object).
- On the Operator settings tab of the SIP-panel 1 object, configure the list of SIP-operators as shown in the figure below (see Operator settings of the SIP-panel interface object).
- Create the Screen 2 object, which will be displayed only on the Agent of Control side (see Assigning the displays to the operator workstations).
- Create child interface object SIP panel 2.
- On the Basic settings tab of the SIP panel 2 object, select the SIP terminal as the terminal (see Basic settings of the SIP-panel interface object).
- On the Advanced settings tab of the SIP panel 2 object configure the list of SIP operators object check the boxes as shown in the figure below (see Advanced settings of the SIP-panel interface object).
- On the Operator settings tab of the SIP-panel 2 object and configure the list of SIP-operators as shown in the figure below (see Operator settings of the SIP-panel interface object).
- On the settings panel of the Computer object, select the speaker and microphone of the SIP operator (see Выбор динамика, микрофона и камеры SIP-оператора).
...