Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

The Intellect section is used for Intellect advanced setup. The settings panel for the Intellect section is shown in the figure.

 Image Modified

The parameters of the Intellect settings panel are described in the table.

No

Parameter name

Field type

Description

Representation

Default value

Value range

1

The Core IP address field with  button. Is set on the Client

Type-in the value in the field/use the  button

Set the IP address of the Intellect server to which the slave.exe module is connected by default.
In case of pressing  button, IP address of the local computer is set.

 


IP address

127.0.0.1

Depends on net settings of the Server. In case of connection failure dialog window requiring IP address is displayed

2

The Keyboard prefix field

Type-in the value in the field

Set the prefix for a special key-board. When a button is pressed on this key-board the Intellect detects when the button was pressed on this very key-board

Symbol

-

Usually, a tilde (~), code 126

The Logging subsystem group

3

The Debug mode dropdown list 

Drop-down list item

Set the mode of the Intellect  Debug window displaying 


List of available modes of Debug window displaying

None 


Disabled Debug window is not displayed.

Debug 1Debug window is displayed  and a log-file containing recordings about modules errors is created.

Debug 2Debug window is displayed and a log-file containing recordings about modules errors and alerts is created.

Debug 3Debug window is displayed and a log-file containing recordings about all the modules events is created.

Debug 4Debug window is displayed and a log-file containing recordings about all the modules events, and also additional menu that is individual for each module (used by programmers) are created.

4

The Log-storing time (hours) field

Type-in the value in the field

Set the time of keeping log files

Sequence

48 hours

> 0

5

The Counters logging time (sec) field

Type-in the value in the field

Assigns the time interval in seconds for logging processor load, memory usage, and disk usage.

Sequence

60

Positive whole numbers not less than 60 and zero. If the value 0 is specified, sensor data is not included in the log file.

6

The Save logs checkbox

Checkbox

Enables logs saving

Boolean type

Yes

Yes – logs are saved.

No – logs are not saved.

7

The Redirect to debugger checkbox

Checkbox

Enables the debugger

Boolean type

None

Yes –the debugger is in use.

No – the debugger is not in use.

8

The Maximum size (MB) field 

Type-in the value in the field

Defines the maximum size of RAM that log files can use. Log files are archived after that size is reached.

Sequence

100 MB

>= 100

Values less than 100 Mb are ignored.

The JPG and AVI files export path group

9

The Default (Intellect\Exp-ort)/Other switch

Set in the position

Set the folder for exported files from Intellect video archive

 

 



-

Default (Intellect\Export) 


Default (Intellect\Export) – exported to the C:\Users\%current user name%\Documents\Intellect\export\ folder

Other – exported to the selected folder

10

The Other field with  the  button

Click the button/type-in the value in the field

Set the pathname to the folder, where files from video archive are to be exported when the switch is set in the Other position

Pathname

-

-

11

The Open folder button

Click the button

Opens the current folder to export the  files

-

-

-

12The Record path checkboxCheckbox

The checkbox forbids export catalogue change while exporting the archive period as well as exporting the archive from AviExport utility.

Boolean typeNo

Yes – export catalogue change is forbidden.

No – export catalogue change is allowed.

No group

13

The Receive uncompressed video checkbox

Checkbox

Enables receiving uncompressed video from the Server. As a rule is set on the Client

Boolean type

No

Yes – Client receives uncompressed video from the Server

No – Client receives compressed video from the Server 


14

The Event viewer over all windows checkbox

Checkbox

Enable displaying the Event viewer window over all windows.

Boolean type

No

Yes – the Event viewer window is displayed over all windows.

No – the Event viewer  window is displayed if a corresponding screen is selected

15

The Only local protocol checkbox

Checkbox

Enables logging the events registered in the given computer to the Events protocol database.

Note. This parameter can be set on the settings panel of the Computer object – see Configuring events logging section.

Boolean type

No

Yes – events registered in the given computer are recorded to the Events protocol database

No – all required events are recorded to the Events protocol database

 


16The Sort tree objects by ID checkboxCheckbox

Enables sorting of objects in the tree by identifier.

Note 1. If sorting by name is selected and the name of the object contains numbers, then the objects are sored in alphabetical order. For example, the object with the name "115" will be higher than the object with the name "15", because in the name "115" there is 1 in the second place, and in the name "15" there is the number 5.

Note 2. This checkbox also affects the sorting of objects in the tree when adding objects to a layer in the Map editor utility.

Boolean typeNo

Yes - objects in the tree are sorted by identifier

No - objects in the tree are sorted by name

1716

The Disable protocol checkbox

Checkbox

Disables events logging to the Event viewer database on this computer.

Note. This parameter can be set on the settings panel of the Computer object – see Configuring events logging section.

Boolean type

No

Yes – events are not logged to the Event viewer database

No – events are logged to the Event viewer database

 


1718

The Used memory dump checkbox

Checkbox

Enables logging .dmp file with a copy of main memory with incorrect shutting down at least one of the system modules to the Intellect root folder

Boolean type

No

Yes – memory dump is created

No – memory dump is not created

1819

The Support old scripts checkbox

Checkbox

Set the support of program tools in Intellect

Boolean type

No

Yes – both scripts and programs are supported

No – only scripts are supported

 


1920

The Time synchronization checkbox

Checkbox

Set time synchronization of all computers in the distributed system with system time of this computer. Time is automatically synchronized at midnight every 24 hours or when INTELLECT™ is started on the Server that is the source of time synchronization.

Boolean type

No

Yes – synchronization is enabled

No – synchronization is disabled


 21

20

The Overlay in Event protocol dropdown list

Drop-down list item

Set the overlay mode for processing the video signals that can be viewed with the help of the Event protocol object

Names of overlay modes

Overlay 2

None – video signals are not processed by video card

Overlay 1 – Direct3D is used

Overlay 2 – DirectDraw is used

2122

The Application language dropdown list

Drop-down list item

Assigns the Intellect Software System's interface language

Names of installed languages

-

Depends on the set of installed languages. The process of installing languages is described in Intellect Software System's interface language.

...