Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  1. Go to the the Main tab of the Incident manager object settings panel.
  2. In the Interfaces for escalation list (1), set the checkboxes opposite other Incident manager objects to which the operator can escalate events.
  3. In the Data server field (2), enter the address of the server to which the data about the operator's actions in the Incident manager should be sent. The default address is http://localhost:5000/.

    Note
    titleAttention!

    This feature is not available in the current Intellect version.


  4. If necessary, set a hotkey, using which the operator can start processing the event. To do this, place the mouse cursor in the "In work" hotkey field (3) and press the required key or key combination on the keyboard.
  5. From the Map drop-down list (4), select the previously created Map object, which will be linked with the Incident manager. The operator can make the object with the event be highlighted on the map.
  6. From the Video drop-down list (5), select a video display mode:
    1. ActiveX - archive and live video will open in a separate window.
    2. Monitor - archive and live video will open on the selected Surveillance Monitor. In this case, the Surveillance Monitor will operate in the Active camera mode, regardless of the corresponding setting - see Configuring the display mode for camera boxes.
  7. In the Number of columns field (6), set the number of columns required to display the event processing logic. The default is 3, the maximum value is 100.

    Info
    titleNote

    The number of columns determines how many Radio button, Checkbox, and Combobox elements elements can be created (see Configuring the elements).

    If the event processing logic is created, and the number of columns is not specified, then when the event is taken into processing, the logic will be displayed incorrectly.


  8. In the Column width field (7), set the width of the columns for the event processing logic display. The width is set in pixels or as a percentage of the entire width of the Incident manager interface. Percentage values ​​should be set in fractions of 1, for example, 0.25. If a value greater than 1 is specified, then it will be taken in pixels. The default column width is 150 pixels.

    Info
    titleExample

    Specified settings: Number of columns - 4, Column width - 100, 300, 300, 100.

    Event processing logic display:


  9. Click the Apply button (8).