Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

XML fileParameterAvailable valuesDefaultParameter in effect
<Directory of the Intellect software installation>\Modules\face_client.run.config

ProblemImagesPath to a folderNone

Specifies the path to the folder for storing images which have been skipped (there are 2 or more faces in the image, or the face was not recognized due to the poor image quality) during the automatic adding of faces from the folder (see Adding images to the reference face database). The specified folder will be created automatically.

Note. If %USER% is specified in the parameter value, the images which haven't been added to the database will be stored in the folder: C:\Users\%LOGGED_USER%\AppData\Local\AxxonSoft\FaceIntellect\ProblemImages\

Timeout>=060000

Specifies the waiting timeout for the face search results in milliseconds.

Port>=010000

Specifies the TCP port for face_client.run.

RemoteUrlIP addressnone

Specifies the sending address of the HTTP POST request. It is used for the images transfer to an external system (see Configuring the images transfer to an external system).

RestRequestInterval>=0500

Specifies the time between the requests of the HUAWEI face recognition module in milliseconds (see Configuring the HUAWEI face recognition module).

AnalitycTimeout>=01000000Specifies the time in milliseconds for refreshing the analytical data in the Face recognition and search interface object. When the time expires, the Operation has timed out error will be displayed (see Viewing the analytical data).
PasserByFramesPerCamera>=010

Specifies the maximum number of comparison results for one camera. A value of 0 means that the number of comparisons is unlimited.

HideViewButtontrue, falseFalse

Hides the “View” button from the interface for monitoring of captured and recognized faces (see Monitoring of captured and recognized faces).

RestRequestInterval>=0500Specifies the time interval in milliseconds between the HUAWEI module requests (see Configuring the HUAWEI face recognition module).
SimpleModetrue, falseFalseEnables the Simple mode of monitoring, which makes the upper part of the Face recognition and search interface window hidden, and such operations as working with the reference face database, face searching in the video archive, and some others unavailable (see Enabling the Simple mode of captured and recognized faces monitoring).
AutoFollowTimeSeconds>=0120Specifies the time in seconds after which the Follow new faces checkbox will be set automatically, if it is unset. The 0 value means that the checkbox will not be set automatically (see Monitoring of captured and recognized faces).
CounterRowCount
>=00Specifies the maximum number of rows (unique faces) in the generated report on analytical data (see Viewing the analytics). The 0 value means there is no limit.
HideCheckBoxIntellectPersontrue, falseFalse

Hides the Create a user in the Intellect database checkbox and assigns a unique Person_ID to each face when adding it to the reference face database (see Adding images to the reference face database).

HideResultsWithoutImagestrue, falseFalse

Hides the face search results with the face images damaged due to the emergency shutdown of the FACE-Intellect server.

<Directory of the Intellect software installation>\Modules64\firserver_replicate.run.config

LogBadImagestrue, falseFalse

Enables saving "bad" photos of faces when the Face database replication module is used (see Face database replication). Photos of faces which could not be added will be saved on the main Server in the folder <Directory of the Intellect software installation>\Modules64\Firserver_replicate_problem_images

...