Panasonic WV-CU950 control panel is connected using 4-wired version of RS-485 interface. Before connecting Panasonic WV-CU950 control panel, make sure that the MODE switches are set to the position corresponding to connection via RS-485 protocol: switches number 1 and number 5 are to be set to ON, the rest to OFF. See details on how to set switches in the reference documentation.
Configure Panasonic WV-CU950 control panel in INTELLECT Axxon PSIM™ as follows:
Set the Panasonic PS-Data interface protocol.
Select the COM port in the Port list.
Set 19200 value for the Speed parameter.
Set the None value for the Parity parameter.
Set the DTR and RTS checkboxes checked.
Create the Control panel system object under the Telemetry controller object.
Configure the Control panel object as described in Configuring Control panel section.
Panasonic WV-CU950 control panel is now configured in INTELLECT Axxon PSIM™.
...
Pressing the key on Panasonic WV-CU950 control panel there is Key pressed or Key released message in INTELLECT Axxon PSIM™.
Description of ‘Key pressed’ and ’Key released’ messages:
...
...