Configuring Panasonic WV-CU950 control panel in Axxon PSIM™

Panasonic WV-CU950 control panel is connected using 4-wired version of RS-485 interface. Before connecting Panasonic WV-CU950 control panel, make sure that the MODE switches are set to the position corresponding to connection via RS-485 protocol: switches number 1 and number 5 are to be set to ON, the rest to OFF. See details on how to set switches in the reference documentation.

Configure Panasonic WV-CU950 control panel in Axxon PSIM™ as follows:

  1. Create the Telemetry controller object.
  2. Configure the Telemetry controller object as follows:

    1. Set the Panasonic PS-Data interface protocol.

    2. Select the COM port in the Port list.

    3. Set 9600 value for the Rate parameter.

    4. Set the None value for the Parity parameter.

    5. Set the DTR and RTS checkboxes checked.

  3. Create the Control panel system object under the Telemetry controller object.

  4. Configure the Control panel object as described in Configuring Control panel section.

Panasonic WV-CU950 control panel is now configured in Axxon PSIM™.

Features of Panasonic WV-CU950 control panel operation in Axxon PSIM™

Pressing the key on Panasonic WV-CU950 control panel there is Key pressed or Key released message in Axxon PSIM™.

Description of ‘Key pressed’ and ’Key released’ messages:

Event

Message

Parameter

Description

KEY_PRESSED

Key pressed

param0

Code of pressed key

KEY_RELEASED

Key released

param0

Code of released key

The Cotrol panel object (TELEMETRY_EXT) is the source of these events. In the comment to these events the code of pressed and released key is specified.

Key codes of Panasonic WV-CU950 control panel:

Key

Key code

Key

Key code

1

'1'

30

'T'

2

'2'

31

'U'

3

'3'

32

'V'

4

'4'

33

'W'

5

'5'

34

'X'

6

'6'

35

'Y'

7

'7'

36

'Z'

8

'8'

37

'a'

9

'9'

38

'b'

10

'0'

39

'c'

11

'A'

40

'd'

12

'B'

41

'e'

13

'C'

42

'f'

14

'D'

43

'g'

15

'E'

44

'h'

16

'F'

45

'i'

17

'G'

46

'j'

18

'H'

47

'k'

19

'I'

48

'l'

20

'J'

49

'm'

21

'K'

50

'n'

22

'L'

51

'o'

23

'M'

52

'p'

24

'N'

53

'q'

25

'O'

54

'r'

26

'P'

55

's'

27

'Q'

56

't'

28

'R'

57

'u'

29

'S'



When the position of Panasonic WV-CU950 joystick is changed, then there is the Position changed message.

Description of Position changed message:

Event

Message

Parameter

Description

Value range

MOVED

Position changed

param0

Offset value

JogDial  -1.. 1; shuttle -6..6

device

Type of control-gear

0 – JogDial,

1 – shuttle

Functions of control panel related to pressing keys can be performed with the help of following:

  1. scripts in JScript (see details on how to create scripts in The Script object. Programming using the JScript language);
  2. programs in internal language in Axxon PSIM;
  3. macros (see details in Administrator's Guide, Creating and using macros section).

The following special features are available for Panasonic WV-CU950 control panel using macros:

  1. Clear screen – allows clearing the device screen.
  2. Type text (set by Y coordinate, Text and Indication parameters) – displaying text with certain position and indication on the device screen.
  3. Set alarm (set by Audio alarm parameter). Set alarm signal type.
  4. Switch on relay (set by Relay identifier parameter). This command allows switching on the indicator.
  5. Switch off relay (set by Relay identifier parameter). This command allows switching off the indicator.
  6. Reboot (set by Reboot type parameter). Allows rebooting the device immediately or after a time period.

Example of JScript script

The file with JScript can be found here. It allows assigning actions to Panasonic WV-CU950 control panel keys:

Key

Function

K

Continuous playback/pause

J

Stop playback

I

Switch to the archive playback mode/view live video mode

N

Clear control panel display

n

Enter key emulation

A

Set the Video surveillance monitor ID

B

Set the camera ID

D

Go to the preset

F

Record preset

i

Layout with 1 camera

j

Layout with 4 cameras

k

Layout with 9 cameras

l

Layout with 16 cameras

Shifting wheel of rotary control

Rewind/fast forward playback

Shifting frame-by-frame wheel

Maximize/minimize the Surveillance window