Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

For instance, to set up Axxon PSIM™ system automatic start for configuration of the Server, the “Shell” parameter is to be identified as: “C:\ Program Files\Axxon PSIM\Axxon PSIMpsim.exe”.

To set up Axxon PSIM™ system automatic start for configuration of the Remote Client, the “Shell” parameter is to be identified as: “C:\Program Files\Axxon PSIM\slave.exe”psim_host.exe.

If the rules of safety of distributed network, a part of which the configured PC is, require that the PC be authorized in the domain, Windows OS may be configured to start without requesting the name (login) and password of the user, who is registered in the domain of the distributed network. This procedure requires assigning a name (login) and a password of the user, which will be used for the PC authorization in the domain by default. To set up Windows OS start without user name (login) and password request, change the following string parameters of the Windows OS registry:

...

#ParameterDefault parameter valueRequired parameter value
1AutoAdminLogon01
2DefaultUserNameOne of the registered user names (logins).User name (login) for authorization in the domain.
3DefaultPasswordIf parameter does not exist, it is to be created.User name for authorization in the domain.

 


Registry parameters are edited either using the Tweaki.exe utility (recommended), or manually. Setup of Axxon PSIM™ system automatic startup with the Tweaki.exe utility is shown in Tweaki.exe utility for advanced setup of the Axxon PSIM software system.

Basic information required for manual system registry editing is outlined in the Working with Windows OS registry section.