Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

In the Axxon PSIM PSIM, you can correct (dewarp) video from fishey fisheye cameras in the Video Surveillance Monitor as well as in all camera windows opened through other interfaces, for instance,

...

  1. Go to the Additional settings tab on the settings panel of the Camera object corresponding to the fisheye camera (1).
  2. Select the Standard fisheye lens valuein the Lens type dropdown list if this is a fish eye camera (2). If a camera with anamorphic lens is in use, then select its type in this dropdown list.
    With some settings there can be some artifacts at the top of video for a standard fisheye lens. If there are such artifacts , then select the Autocalibration in this dropdown list.

    Note
    titleImportant!
    Video will be calibrated every time the settings are applied.


  3. In the Camera location dropdown list select the value corresponding to the camera (3).
  4. Frame edge areas can degrade or loss information as a result of dewarping.   By default, such degraded edges are cut off, i.e. not displayed on the Video Surveillance Monitor. Default visible frame part is 75% for the Ceiling position and 66% for the Wall position. To increase or decrease the displayed frame area, change the value of the Visible part (4) parameter correspondingly. The value of this parameter is chosen experimentally, depending on the camera.
  5. Click the Apply button (5).

...