Go to documentation repository
...
The install file parameter in the command prompt | Description |
/? | Help window call |
/help | Help window call |
/x | The Axxon PSIM software deletion saving the configuration |
/removeall | The Axxon PSIM software deletion without saving the configuration |
/uninstall | The Axxon PSIM software deletion saving the configuration |
/r | The Axxon PSIM software repair |
/repair | The Axxon PSIM software repair |
/qn | The Axxon PSIM software installation/update |
/quiet | The Axxon PSIM software installation/update |
/norestart | Disabling the auto restart of the system while it is being installed |
/LANG=”en” | English language selection of installation program |
/INSTALLTYPE="Client" | Selecting the Monitor workstation installation type |
/INSTALLTYPE="Server" | Selecting the Server installation type |
/INSTALLTYPE="Admin" | Selecting the Admin workstation installation type |
/ADD="[]" | A list of components necessary for installation. Is used if a component that is not installed by default is to be installed. Possible values are given in the next table |
/REMOVE="[]" | A list of components that are not to be installed. Possible values are given in the next table |
/CMD="[commands]" | Values of functions for basic installation program. Where commands mean [Function] =\"[Value]\" or [Function] ='[Value]'. Available functions of installation program are given in the last table in the section |
/debug | Enable verbose logging |
/noOSCheck | Supress checking OS version |
/dpcmd="INSTALL_BOSCH_VIDEOSDK=\"no\"" | Installation of Bosch VideoSDK driver (see Note): no – do not install; yes – install. |
/saveaddons | Do not delete any vertical solutions |
...
Installation program features | Description |
CREATE_QUICKLAUNCH_SHORTCUT='1' | Create quick launch shortcut (is used by default) |
CREATE_QUICKLAUNCH_SHORTCUT='0' | Do not create quick launch shortcut |
CREATE_DESKTOP_SHORTCUT='1' | Create shortcut on the desktop (is used by default) |
CREATE_DESKTOP_SHORTCUT='0' | Do not create shortcut on the desktop |
ADDLOCAL='[]' | A list of components for installation. Available values: 1) Utils – the utilities included in the Axxon PSIM system are installed 2) AxxonSoft VideoDrivers – drivers by AxxonSoft company are installed; 3) Wav – sound notification files are installed. All the components are installed without ADDLOCAL='[]' command. Example. ADDLOCAL='Wav' – Axxon PSIM system and sound notification files are installed. |
REMOVE='[]' | A list of components that are not to be installed. Available values: 1) Utils – the utilities included in the Axxon PSIM system are not installed; 2) AxxonSoft VideoDrivers – drivers by AxxonSoft company are not installed; 3) Wav – sound notification files are not installed. All the components are installed without REMOVE='[]' command. Example. REMOVE ='Utils' – Axxon PSIM, divers drivers and sound notification files are installed. The utilities are not installed. |
Functions of the “Server” and “Admin workstation” installation types | |
INSTALL_AS_SERVICE='1' | Installation as a service |
PATHTOKEYFILE='[%SourceDir%]' | Specify the path to the Key folder with license key |
LANGUAGE='[en]' | Select the language of the Axxon PSIM system |
SQL_AUTHTYPE='Windows' | Selecting the ”Windows accounts” user authentication method |
SQL_AUTHTYPE='Sql' | Selecting the “SQL authentication” user authentication method |
SQL_USERNAME='[sa]' | Setting the user name for the “SQL authentication” method |
SQL_PASSWORD='[]' | Setting the password for the “SQL authentication” method |
General functions: | |
DB_AxxonPSIM_NAME='[Axxon PSIM]' | Specifying the main database. It is not relevant when SQL_AUTHTYPE='Windows' |
DB_TITLES_NAME='[titles]' | Specifying the titles database. It is not relevant when SQL_AUTHTYPE='Windows' |
SQL_INSTANCE='[(local)\SQLEXPRESS]' | Specifying the database server. It is not relevant when SQL_AUTHTYPE='Windows' |
Example of running the Axxon PSIM system installation program in a hidden mode:
...