Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  1. At the Server of Control and Agent of Control side:
    1. Create Audio card object with the Microphone object under it (see Audio subsystem configuration).
    2. Create Audio playback card object with the Speaker object under it (see Configuring audio playback).
  2. At the Server of Control side:
    1. Create a SIP-terminal object as a SIP server in Intellect (see Configuring SIP-terminal).
    2. On the basis of the SIP-terminal object, create 2 child SIP-operator objects and for each of them specify the corresponding operator identification number (Configuring SIP-operators of the Intellect's SIP server).
    3. On the basis of the SIP-terminal object, create the Address book object and select to use the previously created SIP operators (see Configuring address book of SIP-terminal).
    4. On the settings panel of each SIP-operator, select a previously created address book for use (see Configuring SIP-operators of the Intellect's SIP server).
    5. Create a SIP-panel 1 interface object on the same Screen 1 object where the Monitoring interface object was created (see Configuring the SIP-panel interface object).


      Info
      titleNote.
      Recommended coordinates of the SIP panel: X = 40, Y = 40, W = 20, H = 21.


      1. On the Basic settings tab of the SIP panel 1 object, select the SIP terminal as the terminal (see Basic settings of the SIP-panel interface object).
      2. On the Advanced settings tab of the SIP panel 1 object, check the boxes as shown in the figure below (see Advanced settings of the SIP-panel interface object).


      3. On the Operator settings tab of the SIP-panel 1 object, configure the list of SIP-operators as shown in the figure below (see Operator settings of the SIP-panel interface object).


    6. Create the Screen 2 object, which will be displayed only on the Agent of Control side (see Assigning the displays to the operator workstations).
    7. Create child interface object SIP panel 2.
      1. On the Basic settings tab of the SIP panel 2 object, select the SIP terminal as the terminal (see Basic settings of the SIP-panel interface object).
      2. On the Advanced settings tab of the SIP panel 2 object check the boxes as shown in the figure below (see Advanced settings of the SIP-panel interface object).


      3. On the Operator settings tab of the SIP-panel 2 object and configure the list of SIP-operators as shown in the figure below (see Operator settings of the SIP-panel interface object).


    8. On the settings panel of the Computer object, select the speaker and microphone of the SIP operator (see Selecting speaker, microphone and camera for SIP-operator).

...