The Event counter object is designed used to register and count events of a certain type, occurring at the pre-defined specified objects and registered by the INTELLECT™ system Intellect.

The settings panel for the Event counter object is shown in the figure.

Table describes the setting parameters of the settings corresponding to the elements of the settings panel of the Event counter object.

 

Parameter

Method for setting the parameter value

Parameter description

Symbols used

Default value

Value range

1

Identification number*

Automatically

Displays the identification number of the Event counter object in the digital

distributed

video surveillance system

.

with the distributed architecture

Sequence of numbers

-

Depends on the number of the Event counter objects in the digital

distributed

video surveillance system

.

with the distributed architecture

2

Name*

Specify

Enter the value

in

into the field

Sets the name of the Event counter object in the digital

distributed

video surveillance system

.

with the distributed architecture

Latin, Cyrillic and service characters

Event counter

A line containing a sequence of any

symbols

characters (letters, digits, service characters

apart from

except > and <

symbols

characters),

not

case-

sensitive

insensitive.

Number of

symbols –

charactersfrom 1 to 60

.

3

Disable

Set the checkbox

Sets the state (enabled or disabled) of the Event counter object

(enabled or disabled)

in the digital

distributed

video surveillance system

.

with the distributed architecture

Boolean type

No
Clear
Yes – the

Set—the Event counter object is disabled

.

No

Clearthe Event counter object is enabled

.

4

Computer

Select

in

the value from the list

Sets the Computer parent

Computer

object of the digital

distributed video surveillance system

system with the distributed architecture, to which the given Event counter object

refers.

belongs

Name of the Computer objects registered in the system

Name of the Computer parent

Computer

object

.

Depends on the number of the Computer objects in the digital

distributed

video surveillance system with the distributed architecture

The Start to count group

5

From

the date of

(activation)

Set the checkbox

Allows setting manually the

start to count

date and time

manually.

 

 

of the count start



Boolean type

Yes

Set

Set—the 

Yes – the Start to count

date and time of the count start are set manually

.No – The Start to count

Clear—the date and time of the count start are set at the date and time, when the Event counter object was last modified

.

From

the date of

(date)

Specify

Enter the value

in

into the field or select

it in the dropdown list.

the value from the drop-down list

Sets the

Start to count date.

date of the count start

DATE:MONTH:YEAR

Current system date

09.1752 – 12.9999

From

the date of

(time)

Specify

Enter the value

in

into the field

Sets the

Start to count time.

time of the count start

HOURS:MINUTES:SECONDS

Current system time

00:00:0

-

23:59:59

6

From the moment

of counters

counter settings

changing

are changed

Set the checkbox

Sets the

Start to count

date and time of the count start at the date and time, when the Event counter object was last modified

.

Boolean type

No

Clear

Set—the

Yes – the Start to count

date and time of the count start are set at the date and time, when the Event counter object was last modified

.

Clear—the

No – the Start to count

date and time of the count start are set manually

.

7

One counter for all events

Set the checkbox

Sets the same counter for all events

referred to

presented in the Objects and events group of the given Event counter object

.

Boolean type

Yes

Set

Yes – Only

Set—only one counter will be used for counting all events specified in the Objects group

.

No – the

Clear—different events are counted by different counters (each event is counted by

an individual

a separate counter)

.

The

Counter notification

Signal group

8

On

By time (activation)

Set the checkbox

Enables

a

regular notification in

preset periods

a set period of time

.

 


Boolean type

Yes

Set

Set—the notification by time

Yes – on time notification

is enabled

.No – on time notification

Clear—the notification by time is disabled (notification by quantity of events is enabled)

.

On

By time (every)

Specify

Enter the value

in

into the field

Sets

a

the notification period as a time

period

interval. Notification is performed

irrespective

regardless of

on

count start time at 00 minutes 00 seconds of every hour (or at 00 hours 00 minutes 00 seconds of every day

, depending on the time unit settings)

Sequence of numbers

0

0

-

2147483648

On

By time (time unit)

Select the value

in

from the list

Sets a time unit for the

given

notification

.

Line

Hours

Hours

Days

By quantity of events (activation)

Set the checkbox

Enables a regular notification about events

 starting

starting from the

preset

set one

.

Boolean type

No

Clear

Yes

Set—the notification by quantity of events is enabled

.

No

Clear—the notification by quantity of events is disabled (

on

the notification by time

notification

is enabled)

.

By quantity of events (quantity of events)

Specify

Enter the value

in

into the field

Sets

a

the number of event starting from which the notification will be performed.

Example: if the parameter has the value 5

value

, then notification will be performed by every event starting from 5 (5, 6, 7, 8, etc.)

Sequence of numbers

0

0

-

2147483648

The Reset counters group

9

On time

By (activation)

Set the checkbox

Enables a cyclic counter reset in a

preset

set time period

.

 

 



Boolean type

Yes

Set

Yes – a

Set—a cyclic reset in a

preset

set time period is enabled

.

No – a

Clear—a cyclic reset in a

preset

set time period is disabled (By quantity of events (a cyclic reset by quantity of events is enabled)

.

On time

By (every)

Specify

Enter the value

in

into the field

Sets a reset period as a time

period

interval.

Reset is performed

irrespective

regardless of

on

the time of the count start at 00 minutes 00 seconds of every hour (or at 00 hours 00 minutes 00 seconds of every day

, depending on the time unit settings)

.

Sequence of numbers

0

0

-

2147483648

On time

By (time unit)

Select

in

the value from the list

Sets a time unit for the

given

counters reset

.

Line

Hours

Hours

Days

By quantity of events (activation)

Set the checkbox

Enables a counter reset

performed upon occurrence of a preset number of events. 

when it reaches a specified number of event


Boolean type

No

Clear

Set—a

 Yes – a

cyclic reset upon

occurrence of

reaching a

preset

specified number of events is enabled

.

No – a

Clear—a cyclic reset upon

occurrence of

reaching a

preset

specified number of events is disabled (a cyclic reset

on

by time is enabled)

.

By quantity of events (quantity of events)

Specify

Enter the value

in

into the field

Sets a reset period for counters

as a number

by quantity of events

.

Sequence of numbers

0

0

-

2147483648

The Objects and events group

10

Object's type

Select

in

the value from the list

Sets the type of object for which the events are

to be

counted

.

Types

Names of the types of objects registered in the system

.

Not set

Depends on the

number

types of

object types

objects registered in the digital

distributed

video surveillance system

.

with the distributed architecture

Identifier

Select

in

the value from the list

Sets 

Sets the identification number of an object of the

preset

selected type for which the events are

to be

counted

.

Sequence of numbers

Not set

Depends on the number of objects of the given type in the digital

distributed

video surveillance system

.

with the distributed architecture

Object

Object’s

name

Automatically

Displays the identification number of the selected object

.

Latin, Cyrillic and service characters

Not set

Object name

aith

with the

preset

specified identifier

.

11

Event

Select

in

the value from the list

Sets an event that

is to

should be counted

.

Latin, Cyrillic and service characters

Not set

Depends on the

number of

types of objects registered in the digital

distributed

video surveillance system

.

with the distributed architecture

*The name Name of the element is not isn't displayed in the settings panel of the given object.