The Event counter object is designed to register and count events of a certain type, occurring at the pre-defined objects and registered by the INTELLECT™ system.

The settings panel for the Event counter object is shown in figure.

Table describes the parameters of the settings corresponding to the elements of the settings panel of the Event counter object.

 

Parameter

Method for setting the parameter value

Parameter description

Symbols used

Default value

Value range

1

Identification number*

Automatically

Displays the identification number of the Event counter object in the digital distributed video surveillance system.

Sequence of numbers

-

Depends on the number of the Event counter objects in the digital distributed video surveillance system.

2

Name*

Specify the value in the field

Sets the name of the Event counter object in the digital distributed video surveillance system.

Latin, Cyrillic and service characters

Event counter

A line containing a sequence of any symbols (letters, digits, service characters apart from > and < symbols), not case-sensitive

Number of symbols – from 1 to 60.

3

Disable

Set the checkbox

Sets the state of the Event counter object (enabled or disabled) in the digital distributed video surveillance system.

Boolean type

No

Yes – the Event counter object is disabled.

No – the Event counter object is enabled.

4

Computer

Select in the list

Sets the parent Computer object of the digital distributed video surveillance system, to which the given Event counter object refers.

Name of the Computer objects registered in the system

Name of the parent Computer object.

Depends on the number of the Computer objects in the digital distributed video surveillance system

The Start to count group

5

From the date of (activation)

Set the checkbox

Allows setting the start to count date and time manually.

 

 

Boolean type

Yes

Yes – the Start to count date and time are set manually.

No – The Start to count date and time are set at the date and time, when the Event counter object was last modified.

From the date of (date)

Specify the value in the field or select it in the dropdown list.

Sets the Start to count date.

DATE:MONTH:YEAR

Current system date

09.1752 – 12.9999

From the date of (time)

Specify the value in the field

Sets the Start to count time.

HOURS:MINUTES:SECONDS

Current system time

00:00:0 -

23:59:59

6

From the moment of counters settings changing

Set the checkbox

Sets the Start to count date and time at the date and time, when the Event counter object was last modified.

Boolean type

No

Yes – the Start to count date and time are set at the date and time, when the Event counter object was last modified.

No – the Start to count date and time are set manually.

7

One counter for all events

Set the checkbox

Sets the counter for all events referred to the Objects and events group of the given Event counter object.

Boolean type

Yes

Yes – Only one counter will be used for counting all events specified in the Objects group.

No – the events are counted by different counters (each event is counted by an individual counter).

The Counter notification group

8

On time (activation)

Set the checkbox

Enables a regular notification in preset periods of time.

 

Boolean type

Yes

Yes – on time notification is enabled.

No – on time notification is disabled (notification by quantity of events is enabled).

On time (every)

Specify the value in the field

Sets a notification period as a time period. Notification is performed irrespective of on time at 00 minutes 00 seconds of every hour (or at 00 hours 00 minutes 00 seconds of every day – depending on the time unit settings)

Sequence of numbers

0

0 - 2147483648

On time (time unit)

Select the value in the list

Sets a time unit for the given notification.

Line

Hours

Hours

Days

By quantity of events (activation)

Set the checkbox

Enables a regular notification about events  starting from the preset one.

Boolean type

No

Yes – notification by quantity of events is enabled.

No – notification by quantity of events is disabled (on time notification is enabled).

By quantity of events (quantity of events)

Specify the value in the field

Sets a number of event starting from which the notification will be performed.

Example: if the parameter has 5 value, then notification will be performed by every event starting from 5 (5,6,7,8, etc.)

Sequence of numbers

0

0 - 2147483648

The Reset counters group

9

On time (activation)

Set the checkbox

Enables a cyclic counter reset in a preset time period.

 

 

Boolean type

Yes

Yes – a cyclic reset in a preset time period is enabled.

No – a cyclic reset in a preset time period is disabled (By quantity of events (cyclic reset by quantity of events is enabled).

On time (every)

Specify the value in the field

Sets a reset period as a time period.

Reset is performed irrespective of on time at 00 minutes 00 seconds of every hour (or at 00 hours 00 minutes 00 seconds of every day – depending on the time unit settings).

Sequence of numbers

0

0 - 2147483648

On time (time unit)

Select in the list

Sets a time unit for the given reset.

Line

Hours

Hours

Days

By quantity of events (activation)

Set the checkbox

Enables a counter reset performed upon occurrence of a preset number of events.

 

Boolean type

No

 Yes – a cyclic reset upon occurrence of a preset number of events is enabled.

No – a cyclic reset upon occurrence of a preset number of events is disabled (a cyclic reset on time is enabled).

By quantity of events (quantity of events)

Specify the value in the field

Sets a reset period for counters as a number of events.

Sequence of numbers

0

0 - 2147483648

The Objects and events group

10

Object type

Select in the list

Sets the type of object for which the events are to be counted.

Types of objects registered in the system.

Not set

Depends on the number of object types registered in the digital distributed video surveillance system.

Identifier

Select in the list

Sets  the identification number of an object of the preset type for which the events are to be counted.

Sequence of numbers

Not set

Depends on the number of objects of the given type in the digital distributed video surveillance system.

Object’s name

Automatically

Displays the identification number of the selected object.

Latin, Cyrillic and service characters

Not set

Object name aith the preset identifier.

11

Event

Select in the list

Sets an event that is to be counted.

Latin, Cyrillic and service characters

Not set

Depends on the number of types of objects registered in the digital distributed video surveillance system.

*The name of the element is not displayed in the settings panel of the given object.