Go to documentation repository
...
Table describes the parameters of the settings corresponding to the elements of the settings panel of the Keyboard object.
№
| Parameter | Method for setting the parameter value | Parameter description |
Representation | Default value | Value range | ||||
1 | Identification number* | Automatically | Displays the identification number of the Keyboard object in the digital video surveillance system with the distributed architecture | Sequence of numbers | - | From 1 and above. Depends on the number of the Keyboard objects in the digital video surveillance system with the distributed architecture |
2 | Name* | Enter the value into the field | Sets the name of the Keyboard object in the digital video surveillance system with the distributed architecture | Latin, Cyrillic and service characters | Keyboard | A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive Number of |
characters—from 1 to 60 | ||||||
3 | Disable | Set the checkbox | Sets the state of the Keyboard object (enabled or disabled) in the digital video surveillance system with the distributed architecture | Boolean type | Clear | Set |
—the Keyboard object is disabled and isn't used Clear |
—the Keyboard object is enabled and used | ||||||
4 | Computer | Select the value from the list | Sets the Computer parent object of the digital system with the distributed architecture, to which the given Keyboard object belongs | Name of the Computer objects registered in the system | Name of the Computer parent object | Depends on the number of the Computer objects in the digital video surveillance system with the distributed architecture |
The Settings group | ||||||
5 | X | Enter the value into the field | Sets the coordinate on the horizontal X axis of the upper left corner of the object selection window, to which the given command refers | % of the screen width | Not defined | From 0 to 100 |
6 | Y | Enter the value into the field | Sets the coordinate on the vertical Y axis of the upper left corner of the object selection window, to which the given command refers | % of the screen height | Not defined | From 0 to 100 |
7 | Control devices* | Set the required radio button | Sets the interface objects, which will be controlled using the Keyboard | Types of control devices | Operate all | Operate all |
—the Operator can control all interface objects according to the settings in the configuration file of the Keyboard From list |
—the Operator can control only those interface objects, which are sepcified in the list below | ||||||
8 | Type | Select the value from the list | Sets the type of the interface object, which can also be controlled using the Keyboard | Name of the object types registered in the system | Not defined | Depends on the number of the interface object types created in the digital video surveillance system with the distributed architecture |
9 | Number | Select the value from the list | Sets the identification number of the interface object, which can also be controlled using the Keyboard | Sequence of numbers | Not defined | Depends on the number of the created devices of the type selected in item 8 in the digital video surveillance system with the distributed architecture |
10 | Name | Automatically | Indicates the name of the device selected in item 9 | Name of the objects of the selected type registered in the system | Not defined | Depends on the number of the created devices, of the type selected in item 8 in the digital video surveillance system with the distributed architecture |
*Name of the element isn't displayed in the settings panel of the given object.