Go to documentation repository
By default, Incident server events are stored in the PROTOCOL_INC_SERVER table of the Psim database.
If for the Incident server it is necessary to use a database that is different from the one used in Axxon PSIM by default, configure the connection as follows:
In the Connection string, manually enter the connection parameters separated by a semicolon without spaces (3).
Parameter | Possible values |
---|---|
Provider | SQLOLEDB.1 when using MS SQL Server format database, Microsoft.Jet.OLEDB.4.0 when using MS Access database |
Integrated Security | SSPI when authenticating on MS SQL server using a Windows OS account. If MS SQL server is used and the parameter is missing, then username (login) and password will be used for authentication. When using a database in MS Access format, this parameter is not required |
Persist Security Info | True — it —it is permitted to save the password for automatic connection to the database, False — it —it is prohibited to save the password for automatic connection to the database |
Data Source | The name of the MS SQL server used to manage the database, or the path to the MDB file of the MS Access database |
All parameters, except for Integrated Security, are mandatory. Example:
Provider=SQLOLEDB.1;Integrated Security=SSPI;Persist Security Info=True;Data Source=SQLEXPRESS2014
...