Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  1. Select the Protocol report type (see Selecting a type of general report). As a result, the form for specifying the report parameters will be displayed.
  2. In the Objects and events list, select the necessary object type (1).

    Info
    titleNote

    It is possible to select the view of the list of objects and events (see Selecting the view of the list of objects and events for the Protocol report).


  3. From the list of corresponding object types created in Axxon PSIM (2), select the objects for the report. The list of objects of each type is sorted by name. You can also use the Search field (3) to search for the object.
  4. To select the required object, double-click on it or click the  button (4). Click the  button (5) to deselect. The objects selected for the report are displayed in the area 6.

  5. In the area 7, the checkboxes are set next to the object events the information on which will be displayed in the report. By default, all events are selected. Clear the checkbox in order not to include the event in the report.
  6. Set the Report with video checkbox (8) to create the report which will contain the video image from the camera.

  7. From the Camera drop-down list (9), select the camera the video from which will be displayed in the report. You can also search for a camera by its name. To do this, start entering the name of the camera in the field. The search works starting from the first character.

  8. From the Filter drop-down list (10), select the rule by which the data will be filtered when generating the report (7).

    1. No — the —the filter will not be applied.

    2. Equal — the —the report will be generated only for those events where the Information column content is strictly equal to the filter value specified in the Filter text field (11).

    3. Contains — the —the report will be generated only for those events where the Information column contains the filter value specified in the Filter text field (11).

      Info
      titleNote

      The report is filtered only by the Information column (see the report fields description in the table below).


  9. In the Filter text field (11), enter the value for the report filtering.

  10. In the Maximum of output strings field (12), enter the maximum number of output strings in the protocol report.
  11. From the Period drop-down list (13), select the time period for which the report should be created.

    Info
    titleNote
    • If the Custom period is selected, enter the date of start and end periods for which the report should be created in the from and to fields using the Calendar tool. Click the  button near the corresponding field to use the Calendar tool.
    • If the Custom 2 period is selected, enter additionally the time of start and end periods for which the report should be created using the  button.


  12. Click the Execute button (14) to generate the report.

...

Info
titleNote

...