To assess an alarm event, use the group of colored buttons in the lower left corner of the Alarm Management window. After assessing the alarm, the Surveillance window on the given Client automatically switches to Live Video mode. The corresponding alarm event is no longer in the Alarms tab.

Note
titleAttention!

In the case of multi-user alarm event processing, only the first operator who switched to the Alarm Management mode can assess the alarm event (if they have the appropriate permissions). For the rest of the operators, the alarm event assessment buttons are not displayed.

...

Button

Executed function

Confirmed alarm event

Suspicious alarm event

False alarm  event

When you click the Image Added button, a window opens with the possibility of setting the visibility area for the roles whose users will be able to see the alarm, as well as change the alarm priority for the selected role. If you want to change the alarm priority for all created roles in the system, set the All checkbox.

Image Added