Go to documentation repository
Page History
Section | |||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Configuring detection tool
To configure the Move From Area To Area, do the following:
- Create the required detection tool and specify its parameters (see Creating detection tools).
- Below the created detection tool, click Create… → Move From Area To Area.
By default, the detection tool is enabled and triggers when an object leaves one area and enters another area.
If necessary, you can change the detection tool parameters. The list of parameters is given in the table:
Parameter | Value | Description | |||||
---|---|---|---|---|---|---|---|
Other | |||||||
Enable | Yes | The detection tool is enabled by default. To disable the detection tool, select the No value | |||||
No | |||||||
Name | Move From Area To Area | Enter the detection tool name or leave the default name | |||||
Type | Move From Area To Area | Name of the detection tool type (non-editable field) | |||||
Advanced settings | |||||||
X-axis offset | 15 | Specify the X-axis and Y-axis offsets as a percentage of the track area to set the area of the detection tool triggering. The values must be in the range [1, 50] | |||||
Y-axis offset | 10 | ||||||
Basic settings | |||||||
Event hold time (sec) | 2 |
This is the time period during which the detection tool waits for the next objects after the first object in the group is detected. If the specified number of objects (specified in the Number of alarm objects parameter) are detected within this time period, the detection tool triggers. If no additional objects are detected within the specified time period, the detection tool doesn't trigger. | |||||
Maximum object height | 100 | Specify the maximum object height as a percentage of the frame size for the detection tool to trigger. The value must be in the range [0.05, 100]
| |||||
Maximum object width | 100 | Specify the maximum object width as a percentage of the frame size for the detection tool to trigger. The value must be in the range [0.05, 100]
| |||||
Maximum speed | 500 | Specify the maximum object speed per second for the detection tool to trigger. The value must be in the range [0, 500]
| |||||
Minimum object height | 0.1 | Specify the minimum object height as a percentage of the frame size for the detection tool to trigger. The value must be in the range [0.05, 100]
| |||||
Minimum object width | 0.1 | Specify the minimum object width as a percentage of the frame size for the detection tool to trigger. The value must be in the range [0.05, 100]
| |||||
Minimum speed | 0 | Specify the minimum object speed per second for the detection tool to trigger. The value must be in the range [0, 500]
| |||||
Number of alarm objects | 2 |
This number determines the minimum number of objects that are considered a group and can cause the detection tool triggering. | |||||
Object class | All classes | Select the object class that must trigger the detection tool. The default value is All classes
|
| |||||||
Vehicle | |||||||
Person | |||||||
Trigger on group of objects | Yes | The parameter is disabled by default. If you want the detection tool to trigger only for a group of objects, select the Yes value
| |||||
No |
To save the parameters of the detection tool, click the Apply button. To cancel the changes, click the Cancel button.
Configuring detection areas
...