Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Note
titleAttention!

The Abandoned objectObject detection can operate only with the Object trackerTracker detection tool.

Before you create and configure the Abandoned objectObject detection, do the following:

  1. Create the Object trackerTracker detection tool and set its general parameters (see Configuring the Object Tracker).
  2. Configure some parameters of the Object Tracker detection tool as follows:
    ParameterValueDescription
    Auto sensitivityYesIf auto sensitivity is enabled, sensitivity adjustments for moving and abandoned objects are not applied. To apply manual sensitivity adjustments, it is necessary to disable the auto sensitivity
    Long-time abandoned object detectionYesIf you enable this and the Enable filter parameter (see Configuring the Object Tracker), it can reduce the number of false positives during detection
    Abandoned object detectionYesObjects abandoned for 10 seconds or longer will be detected
    Alarm on object's max. idle time in area60

    Specify the time in seconds—if the object remains idle for the time longer than the specified, it will be detected. This value

    should

    must be in the range [15, 1800].

    Info
    titleNote

    This parameter is used only for the Long-time abandoned object detection. It is recommended to select the parameter value starting from 15.


    Abandoned object detection sensitivity20

    For this parameter to work, it is necessary to first disable the Auto sensitivity parameter.

    Set the sensitivity for abandoned object detection and long-time abandoned object detection in the range [1, 100].

    Info
    titleNote

    This parameter depends on the lighting conditions and

    should

    must be chosen empirically. It is recommended to select the parameter value starting from 20.


  3. Save the detection tool parameters by clicking the Apply button.

...

ParameterValueDescription
Other
EnableYesBy default, the detection tool is enabled. To disable, select the No value
No
NameAbandoned Object
Enter a detection tool name or leave the default name
TypeAbandoned ObjectDetection tool type name (non-editable field)
Basic settings
Maximum object height100

Set the maximum height of the object that should trigger must generate an event from the detection tool, as a percentage of the frame size. The value should must be in the range [0.05, 100]

Maximum object width100Set the maximum width of the object that should trigger must generate an event from the detection tool, as a percentage of the frame size. The value should must be in the range [0.05, 100]
Minimum object height0,1Set the minimum height of the object that should trigger must generate an event from the detection tool, as a percentage of the frame size. The value should must be in the range [0.05, 100]
Minimum object width0,1Set the minimum width of the object that should trigger must generate an event from the detection tool, as a percentage of the frame size. The value should must be in the range [0.05, 100]
Note
titleAttention!

In the settings of the Object trackerTracker detection tool and the Abandoned objectObject sub-tool, the values of the maximum and minimum height and width of the object should must be equal.

Object type

BroughtSelect a value if it is necessary to detect an object that has disappeared from the observed area and crossed its boundaries
Abandoned
Any

Select this value if it is necessary to detect both brought and abandoned objects

...

To save the parameters of the detection tool, click the Apply  button. To cancel the changes, click the Cancel  button.