Go to documentation repository
Page History
...
If necessary, you can change the detection tool parameters. The list of parameters is given in the table:
Parameter | Value | Description |
---|---|---|
Other | ||
Enable | Yes | The detection tool is enabled by default. To disable the detection tool, select the No value |
No | ||
Name | Signal Detection | Enter the detection tool name or leave the default name |
Type | Signal Detection | Name of the detection tool type (non-editable field) |
Basic settings | ||
Alarm end delay | 10 | Enter the time in seconds during which the generation of an event won't stop after the noise stops. If noise is detected again within the specified time, it |
is considered as one event | ||
Percentage of noise in audio stream | 2 | Specify the threshold value of noise in the audio stream as a percentage. If the value is exceeded, the detection tool |
generates an event. You must select the value empirically in the range [0, 100] |
To save the parameters of the detection tool, click the Apply button. To cancel the changes, click the Cancel button.
Overview