If necessary, you can change the detection tool parameters. The list of parameters is given in the table:

ParameterValueDescription
Other
EnableYesThe detection tool is enabled by default. To disable the detection tool, select the No value
No
NameNoise DetectionEnter the detection tool name or leave the default name
TypeNoise DetectionName of the detection tool type (non-editable field)
Basic settings
Alarm end delay10Enter the time in seconds during which the generation of an event won't stop after the noise stops. If noise is detected again within the specified time, it
will be
is considered as one event
Percentage of noise in audio stream2Specify the threshold value of noise in the audio stream as a percentage. If the value is exceeded, the detection tool
will generate
generates an event. You must select the value empirically in the range [0, 100]

To save the parameters of the detection tool, click the Apply  button. To cancel the changes, click the Cancel  button.