Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

To detect objects with a speed less than 0,3 m/s, the following settings are recommended:

  1. The number of frames for analysis and output: 3.
  2. The number of frames processed per second: 1.
  3. Neural filter: No.
  4. Recognition threshold: 30.
  5. Neural network file: Path to the *.ann neural network file. You can also select Object type—in this case, this field should be left blank.
Info
titleNote

By default, the neurocounter is configured for detection of objects with a speed less than 0,3 m/s.

To solve tasks in which the speed of the object is greater than 0,3 m/s, it is necessary to increase the number of processed frames and/or reduce the number of frames for analysis and output. The values ​​are selected by trial-and-error method depending on the conditions of the task.