Documentation for Axxon One 2.0. Documentation for other versions of Axxon One is [available too].

Previous page Next page

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 2 Current »

To detect objects with a speed less than 0,3 m/s, the following settings are recommended:

  1. The number of frames for analysis and output: 3.
  2. The number of frames processed per second: 1.
  3. Neural filter: No.
  4. Recognition threshold: 30.
  5. Neural network file: Path to the *.ann neural network file. You can also select Object type—in this case, this field should be left blank.

Note

By default, the neurocounter is configured for detection of objects with a speed less than 0,3 m/s.

To solve tasks in which the speed of the object is greater than 0,3 m/s, it is necessary to increase the number of processed frames and/or reduce the number of frames for analysis and output. The values ​​are selected by trial-and-error method depending on the conditions of the task.