Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Tip

Controlling a PTZ сamera

The PTZ object is displayed in the objects object tree as the a child object to the camera , if it is the a PTZ camera.

To configure the PTZ device of the camera, do the following:

  1. Go to the Devices tab.
  2. Select
  3. the
  4. the PTZ object in the
  5. objects
  6. object tree
  7. (1).
    Image Removed
  8. Enable the PTZ device by selecting Yes in the Enable field (2).
  9. Enter the name of the PTZ device (3).
  10. . If necessary, you can change the values of the parameters that are listed in the table:
    ParameterValueDescription
    Object identification
    EnableYesBy default, PTZ is enabled. To disable it, select the No value
    No
    NamePTZEnter the name of the PTZ device
    PatrolYes

    By default, patrolling is disabled. To enable it, select the Yes value. If patrolling is enabled, you can stop it on the PTZ control panel (see Patrolling). After you finish the PTZ control session, patrolling resumes automatically

    No
    Save presetsYes

    By default, the parameter is disabled. In this case, the presets are only stored on the server. To save the created presets to the IP device, select the Yes value

    Info
    titleNote

    This parameter is available only for the devices that support Absolute Positioning.

    No
    Switch interval1Specify the time interval in seconds at which the PTZ device switches between the presets in the patrol mode. The value must be in the range [1, 600000]
    Tag & Track
    PriorityNoneSelect the control priority (see Setting PTZ mode for Tag&Track Pro)
    Manual
    Automatic
    User priority
    Manual PTZ control
    Switch Frequency3Specify the switch frequency in seconds

    Other

    Note
    titleAttention!

    Depending on the camera, you can find other parameters in the Other group. To configure them, refer to their description in the interface or in the official documentation.

    Discrete control via continuous control YesBy default, the parameter is disabled. If you need to use the step buttons to control the PTZ camera even if the camera
  11. does not
  12. doesn't support this mode, select
  13. Yes for the Discrete control via continuous control parameter (4, see
  14. the Yes value (see Control using step buttons and virtual joystick). In this case, the discrete PTZ control
  15. will be
  16. is emulated via the continuous control commands
  17. No
    Home preset0Select the
  18. Home
  19. home preset by specifying the required identifier
  20. (5). The home preset will return
  21. Home preset timeout0

    The return to the home preset is performed automatically after the time

  22. period
  23. specified in the

  24. Home preset timeout field (6).
  25. parameter

    Note
    titleAttention!

    If

  26. the
  27. the Home preset timeout value is greater than the Operator idle time value (

  28. see
  29. see Configuring PTZ control), the Operator idle time value

  30. will be
  31. is used.

  32. To simultaneously control the PTZ camera by
  33. Multiple controlYes

    By default, the parameter is enabled, which allows multiple users with the same priority to control the PTZ device at the same time. To disable multiple control, select

  34. Yes in the Multiple control list (7). Otherwise,
  35. the No value. In this case only one user at a time

  36. will
  37. can have

  38. a
  39. .
  40. No
    New PTZ interfaceYes

    By default, the parameter is disabled. To use the existing presets on the device in Axxon One,

  41. set Yes for the New PTZ interface parameter (8)
  42. select the Yes value. The presets created on the device

  43. will
  44. automatically appear in the PTZ control panel

  45. .
  46. Note
    titleAttention!

    If the use of the existing presets is disabled, they can be lost if the following conditions are met:

  47. 1. The
    1. In Axxon One, the recording of the presets to the device is enabled in
  48. Axxon One (see step 9)
    1. the Use device presets parameter.
  49. 2.
    1. The preset with the same ID is created
  50. in
    1. in Axxon One
  51.  
  52. Configure patrol:
  53. Select the default patrol mode: Yeson, Nooff (9). If patrolling is enabled by default, it can be stopped in PTZ control panel (see Patrolling). After you finish the PTZ control session, patrolling will resume automatically.
  54. Set the time interval in seconds at which the PTZ device will switch between the presets in the patrol mode (12).
  55. No
    Patrol speed100Specify
  56. Set
  57. the transition speed from one preset to another in conditional units from 0 to 100
  58. (10).
  59. Use device presetsYesBy default
  60. , the presets are recorded in the IP device. If you want to store the presets on the Server only
  61. ,
  62. select No for
  63. the
  64. Save presets parameter (11).
    Info
    titleNote

    This parameter is available only for the devices that support Absolute Positioning.

  65. parameter is disabled. To create the presets with the same ID in Axxon One (
  66. see
  67. set Yes for the Use device presets parameter (13).
  68. If necessary, configure the Tag & Track function (14, see Configuring Tag&Track Pro).

  69. Depending on the camera, you can find other parameters in the Other group (15). To configure them, refer to their description in the interface or in the official documentation.
  70. select the Yes value
    No
    Camera
    Camera{Short name.Name}

    If necessary, select the camera to which this PTZ device must be assigned

  71. to
  72. (

  73. 16
  74. see Camera). As a

  75. results
  76. result, the object

  77. will become the
  78. becomes a child object to the selected camera

  79. .
  80. Click the Apply Image Added button.

As a result, the PTZ device will switch is switched to the specified operating mode.