Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

The settings panel for the Incident handler object is shown in the figures. The description of the Incident handler setting parameters is given in the tables.

Object general settings and the Filters tab

Parameter

Method for setting the parameter value

Parameter description

Representation

Default value

Value range

1

Identification number*
field

Automatically

Displays the identification number of the Incident handler interface object in the video surveillance system with distributed architecture

NumbersDigits, letters, periods, hyphen, dash, and underscore

NA

Depends on the number of the Incident handler objects in the video surveillance system with distributed architecture

2

Name*
field

Enter the value in the field

Sets the name of the Incident handler object in the system

Latin alphabet, Cyrillic, digits and service characters 

Incident handler

A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive.

Number of charactersfrom 1 to 60

3

Disable
checkbox

Set the checkbox

Disables the Incident handler object 

Boolean type

Clear

Setthe Incident handler object is disabled and isn't used

Clearthe Incident handler object is enabled and used

4Incident server
drop-down list

Select the value from the list

Sets the Incident server parent object for the given Incident handler objectNames of the Incident server objects registered in the system Name of the Incident server parent objectDepends on the number of the Incident server objects in the system
The Filters tab
The Objects table

5

Type
drop-down list

Select the value from the list

Sets the type of objects for which the events must be displayed in the Incident manager window

Available object types

NA

Depends on the objects registered in the system.

Only those object types are available for selection for which the "INFORMATION" or "ALARM" value is selected on the Events tab in the Processing messages column in the ddi.exe utility (see The Events tab)

Number
drop-down list

Select the value from the list

Sets the number of the object for which the events must be displayed in the Incident manager window

Sequence of numbers

NA

Depends on the number of the objects of the specified type registered in the system

Name
field

Automatically

Sets the name of the object for which the events in the Incident manager window must be displayed

Names of the objects registered in the system

NA

Depends on the objects registered in the system

Event type
drop-down list

Select the value from the list

Sets the events displayed in the Incident manager interface window

Events available for the selected object

NA

Depends on the selected object type

Area
drop-down list

Select the value from the list

Sets the Areaarea, the events from which are displayed in the  Incident incident manager window

Areas available for the selected object

NA

Depends on the selected object type and Areas areas registered in the system

Region
drop-down list

Select the value from the list

Sets the Regionregion, the events from which are displayed in the Incident incident manager window 

Regions available for the selected object

NA

Depends on the selected Areaarea

Logic
drop-down list
Select the value from the list

Sets the logic that is used to handle the events of the corresponding object.

Note. The logic must be specified. Otherwise, the selected events aren't displayed

Logic NA

A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive.

Number of charactersfrom 1 to 255

Logic listNA

Depends on the created Logic objects on the Logic tab

Priority
drop-down listPriority
Select the value from the listSets the priority level for events of the corresponding objectPriority levellevels specified on the Main tab0Depends on the priority templates created on the Main tab
Timer (s)
field
Enter the value in the fieldSets the time in seconds from the moment the event occurs, after which the TIME_IS_OVER event is generated. The timer will also count down the specified time in the interface in the Time (s) column until it reaches zeroTime in secondsNA>=0

Autoescalation (s)
field

Enter the value in the field

Sets the time in seconds from the moment the event occurs, after which the event is automatically escalated. Autoescalation is performed within one Incident incident manager and works if the operator has the escalation rights

Time in seconds

NA

>=0

6Add
button
Click the buttonOpens the window for selecting events as a group (see Displaying and handling events in bulk)NANANA
7Clear
button
Click the buttonClears the table with the selected objects and eventsNANANA

*Name of the element isn't displayed in the settings panel of the given object.

The Logic tab

ParameterMethod for setting the parameter valueParameter descriptionRepresentationDefault valueValue range
1Create copy
button
Click the buttonIf you select a logic in the list of logics and click on the this button to create a copy, a copy of the selected logic is created. It will appear in the list of logics. The name of the new logic consists of the name of the original logic and the copy number in brackets. For example, for Logic 1, the first copy is named Logic 1(1), the second copy is named Logic 1(2)NANANA
2+ buttonClick the buttonCreates a new Logic  objectNANANA
3

-  button

Click the buttonRemoves the Logic  object selected  selected in the logic listNANANA

4

List of logics*
area

Select the value from the list

Selects the logic which elements are displayed in the list on the rightList of the created logicsNADepends on the number of the created logics

The Editing logic table

5

Starting
checkbox
Set the checkbox

Selects the element that is displayed first for the operator when processing the event.

To set the checkbox, do the following:

  1. Select an element in the table.
  2. Click the Edit button.
  3. In the Starting element drop-down list, select Yes.
  4. Click the OK button
Boolean typeClear

Only one element in the logic can be the starting one.

Setthe element is the starting element in the logic

Clearthe element isn't a starting element in logic


6

Element ID
field
Enter the value in the fieldEnters Sets the element nameLatin alphabet, Cyrillic, and service characters NAFrom 0 to 255 characters

7

Element type
drop-down list

Select the value from the list

Sets the element type (see Configuring the elements)Available element typesNA
  • Image;
  • Button;
  • SwitchRadio button;
  • Comment;
  • Combobox;Field with list
  • Date/time;
  • Checkboxes
8Multitasking
drop-down list
Select the value from the listLimits the ability to switch to processing another event another event if the operator is on the selected element.Available multitasking valuesBy default, when processing an event, you can move on to processing other events from any element of logic.
  • Denywhen the selected element appears, the operator can cannot switch to processing another event until the operator moves to the element with the Allow value or completes processing the event;
  • Allowwhen this element appears, the operator can proceed to processing another event;
  • Blank fieldthe multitasking setting of the previous logic element is applied to the selected element

9

Edit
drop-down list
Select the value from the list

Allows stepping back when processing an event

Available valuesBy default, when processing an event, you can step back
  • Deny—you cannot step back
  • Allow—you can step back

Out of the group

10

Edit
button

9

EditClick the button

Opens a window for editing the selected element (see Configuring the elements)

NANA

NA

1011

Apply to processed events
checkbox
Set the checkbox

Resets the event processing.

The option works if the administrator has changed the Logic, clicked Apply, and wants to apply use the updated Logic to logic for events in the Incident incident manager

Boolean typeClear

Set—the event processing with the selected Logic logic is reset, and the event can be processed again with the updated Logiclogic

Clear—the Logic logic will change, but the started event processing job operation with this Logic logic isn't reset. The updated Logic logic is applied only to subsequent new events

...

*Name of the element isn't displayed in the settings panel of the given object

The Main tab

 group

ParameterMethod for setting the parameter valueParameter descriptionRepresentationDefault valueValue range
The Priority localization template table
1Priority 
field
Enter the value in the fieldSets the priority levelPriority levelNANumeric value, positive integer
2Value 
field
Enter the value in the field

Sets the priority description. If the priority description is set, then it is displayed in the Incident incident manager, otherwise, the priority level is displayed

Priority descriptionNA

A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive.

Number of charactersfrom 1 to 255

The Columns settings group
3Count
field
Enter the value in the field

Sets the number of columns when displaying the event processing logic in the  Incident incident manager interface

Sequence of numbers4From 0 to 100
4Columns width 
field
Enter the value in the field

Sets the width of the columns when displaying the event processing logic in the  Incident incident manager interface

Pixels or fractions150 pixelsPercentage values ​​must be set in fractions of 1, for example, 0.25. If a value greater than 1 is set, then it is taken in pixels

...