To configure alarm processing in the system, do the following:
- Go to Settings → Options(1) → Alarm processing(2).
In the . - Enter the required parameter settings specified in the table:
Parameter Value Description Alarm processing Time period of operator reaction to alarm field (3), enter [hours], [minutes], [seconds] Enter the time during which
the an alarm must be taken into processing
, otherwise . Otherwise it is assigned the Skipped status. The
minimum default value is 5 minutes. To change the time limit, specify a value in the range:
- hours [0, 96]
- minutes [2, 59]
- seconds [0, 59]
Note title Attention! Minimum time limit is 0 hours, 2 minutes, 0 seconds.
Info title Note - To take an alarm into processing, you must switch to the Alarm management mode (see Switching to the Alarm management mode).
- After you take an alarm
is taken - into processing, the time for handling it is unlimited.
Set the maximum time for an alarm to stay on a special layout (4Time a camera is on alarm layout [hours], [minutes], [seconds] Enter the time during which an alarm is displayed on the alarm layout (
, see Working with Special layouts). After the specified time has elapsed, the alarm is removed from the layout, and its place is taken by the next alarm, which has not yet been displayed on the layout.
By default, the time isn't set. To change the time limit, specify a value in the range:
- hours [0, 96]
- minutes [2, 59]
- seconds [0, 59]
Mandatory comment Confirmed alarm By default, when an alarm is triggered, a comment isn't provided (the checkbox is clear). If a mandatory comment is required, set the checkbox Suspicious situation By default, when an alarm is triggered, a comment is provided (the checkbox is set). If a mandatory comment isn't required, clear the checkbox False alarm By default, when an alarm is triggered, a comment isn't provided (the checkbox is clear). If a mandatory comment is required, set the checkbox - Click the Apply
Select the alarm assessment, after accepting which, the operator is required to enter a comment (5).
- Click the Apply button.
Configuration of alarm processing is now complete.