Connection of BioSmart ACS controllers of all types is configured the same way.
BioSmart ACS controller is connected to ACFA Intellect as follows:
...
- Create the Computer (LOCALHOST)-based BioSmart2 object in the Hardware tab of the System System settings dialog box (Fig. 3.21). Each controller corresponds to the BioSmart2 object.
...
...
- Go to the settings panel of the BioSmart2 object (Fig. 3.22).
...
...
- Select the controller connection type in the corresponding list (Fig. 3.22, 1).
- If connection is performed via RS-485 standard, then specify the COM port number and speed of its connection (Fig. 3.22, 2).
- If connection is performed via Ethernet standard, then specify IP address and controller port (Fig. 3.22, 3).
- Click the Apply button to save all changes.
- Create the Biosmart 4 or BioSmart PROX (BioSmart PROX v.2 controller corresponds to this object if connection is performed via RS-485 standard BioSmart PROX-E controller if connection is performed via Ethernet standard, Fig. 3.23) controller object on the base of the BioSmart2 object.
...
- On the settings panel of the created object specify the address serial number of controller in controller BioSmart ACS internal network (Fig. 3.24).
...
- .
- Click the Apply button.
Info | ||
---|---|---|
| ||
Only one server (Intellect or Biosmart software) can be connected to a controller at a time. If some software has connected to the controller, other servers are not able to establish connection |
...
. |
BioSmart ACS controller is now connected to ACFA Intellect.