Go to documentation repository
Page History
INTELLECT™ provides the PTZ control option using the Operator query panepanel interface object. The Operator query panepanel interface object is an individual user dialog box with the relevant elements to control a certain type of PTZ device.
...
Create and configure the Operator query panepanel as follows:
- Open the Programming tab in the System settings dialog box (1).
Create a Macro object under the Macros object in the Programming tab (2). Specify the object's ID and name.
Info title Note The Macro object is necessary to refer to INTELLECT™ core and to display the Operator query panepanel on the screen.
- Open the Hardware tab in the System settings dialog box (3).
- Create the Operator query panepanel object under the Computer object in the Hardware tab (4).
- Specify the file name (without extension) of the dialog box, used for PTZ device control, in the ID field (5). The necessary files are stored in the program folder of the INTELLECT™ installation directory.
- To activate the moving option for the Operator query panepanel object, set the Allow moving checkbox checked (6).
- Specify the X and Y coordinates of the Operator query panepanel position on the screen in the relevant fields. The X and Y settings correspond to the screen coordinates of the top left corner of the Operator query panepanel and are shown as percentage of the horizontal and vertical screen sizes correspondingly (7).
- Select the type of the Macro objects in the list of objects and events (8).
- Specify the ID of the Macro object, created to call up the Operator query panepanel (9).
- The name of selected Macro object is automatically displayed in the Name column (10).
- Select the Action executed executed item in the list of possible events (11).
- To save the changes click the Apply button (12).
Overview
Content Tools