Table of Contents

General information

The status bar displays:

  • CC - the start of the displayed period for the current cell column.
  • LL - the time when the data was last loaded into the database.
  • OB -

...

  • the total number of

...

  • "not ignored

...

  • " objects.
  • FO - the number of objects with hardware problems

...

Image Removed

The status panel also shows the beginning of the time period for the column of the current cell (CC), time at which data was most recently loaded into the database (LL).

The status panel also shows the index of functionality (IF) for the system and index of non-functionality (IN) for each of the reasons.

Note
titleImportant!

The rates are not calculated if the Alarms, Failures or Disconnected filter is enabled – see The number of alarms displayed.

The IF is calculated as follows:

(1-Nnfo/Nt)*100

  • Nnfo – number of objects that are not fully operable
  • Nt – total number of objects

Indexes of non-functionality  for each reason are calculated as follows:

(1-Nnfor/Nt)*100

  • Nnfor – number of objects that are not fully operable due to this reason
  • Nt – total number of objects

Indexes are calculated for non-ignored objects only. Indexes are not calculated and filters are never used for ignored objects. Indexes of non-functionality equal to 0 are not shown on the status panel.

  • displayed at a given time.
  • Cam - the camera statistics: total number of cameras at the facilities/number of working cameras/number of faulty cameras.
  • IF% - the video surveillance system functioning rate.
  • IN% - the video surveillance system non-functioning rate by reasons.

Image Added

You can hover the mouse cursor directly over the status bar to display a tooltip.

Image Added

Note
titleImportant!

If filtering is enabled, then in order to calculate rates (IF% and IN%) and camera statistics (Cam) only for filtered objects, click Image Added (Calculate rates and cameras only for filtered table lines).

Functioning and non-functioning rates

Info
titleNote

Functioning (IF%) and non-functioning (IN%) rates are calculated only for “not ignored” objects. For “ignored” objects, rates are not calculated and the filter is never used (see Ignoring objects). Zero values of non-functioning rates are not shown on the status bar.

Rates (IF% and IN%) are not calculated if Alarms, Failures or Disconnected filter is enabled (see The number of alarms displayed on the Log panel).

Functioning rate (IF%) is calculated according to the following formula:

(1-Nnf/Na)*100, where

  • Nnf is the number of objects that do not function properly.
  • Na is the total number of objects

The non-functioning rate (IN%) for a particular reason is calculated according to the following formula:

(Nnfbr/Na)*100, where

  • Nnfbr is the number of objects that do not function properly for this particular reason
  • Na is the total number of objects

...