The status panel shows the total number of non-ignored objects (OB) and number of objects with hardware problems (FO) that are currently displayed.

The status panel also shows the beginning of the time period for the column of the current cell (CC), time at which data was most recently loaded into the database (LL).

The status panel also shows the index of functionality (IF) for the system and index of non-functionality (IN) for each of the reasons.

Important!

The rates are not calculated if the Alarms, Failures or Disconnected filter is enabled – see The number of alarms displayed.

The IF is calculated as follows:

(1-Nnfo/Nt)*100

  • Nnfo – number of objects that are not fully operable
  • Nt – total number of objects

Indexes of non-functionality  for each reason are calculated as follows:

(1-Nnfor/Nt)*100

  • Nnfor – number of objects that are not fully operable due to this reason
  • Nt – total number of objects

Indexes are calculated for non-ignored objects only. Indexes are not calculated and filters are never used for ignored objects. Indexes of non-functionality equal to 0 are not shown on the status panel.

If filtering is used and you want to calculate percentages in the status panel for filtered objects only, click the  button ("Count indexes only in filtered table strings").