Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Function menu command

Executed function

Switch mode

Sequentially switches the sensor operation modes.

The following modes are available for the Forteza sensors:

  • Duty mode - displays the interference level
  • Adjustment - displays the signal level
  • Thresholds - displays the current threshold value

The following modes are available for the MIR sensors:

  • Duty mode - displays the interference level
  • IR adjustment - displays the signal level of the infrared channels

  • RB adjustment - displays the signal level of the radio ray (radio beam) channels

  • Thresholds - displays the current threshold value
Handle alarmsAlarm confirmation by the operator
ArmArms the sensor
SettingsOpens the sensor configuration window
DisarmDisarms the sensor
Change threshold

Sequentially switches the trigger threshold in the range from 0.25V to 1V and the 0.1V interval

...

Info
titleNote

After the adjustment is made and the threshold values are set, the sensors should be switched to the duty mode and the Period of indicator updating parameter value should be set to Do not use. These actions will improve the general responsiveness of the system (see Configuring Forteza two-position sensor).


Info
titleNote

For the Format sensors, an alarm is generated only when it occurs simultaneously on the IR and RB channels.

...