Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

To

...

configure the

...

Signal detector, do the following:

  1. Go to the 

...

  1. Detectors tab.

  2. Below the required camera, click Create… → Category: Service →

...

  1. Signal detector.

By default, the

...

detector is enabled and set to detect signals.

If necessary, you can change the

...

detector parameters. The list of parameters is given in the table:

ParameterValueDescription
Other
EnableYesThe
detection tool
detector is enabled by default. To disable the
detection tool
detector, select
the 
the No
 value
 value
No
Name
Signal Detection
Signal detectorEnter the
detection tool
detector name or leave the default name
Type
Signal Detection
Signal detectorName of the
detection tool
detector type (non-editable field)
Basic settings
Alarm end delay10Enter the time in seconds during which the
triggering
generation of an event won't stop after the noise stops. If noise is detected again within the specified time, it
will be
is considered as one event
Percentage of noise in audio stream2Specify the threshold value of noise in the audio stream as a percentage. If the value is exceeded, the
detection tool will trigger. You
detector generates an event. You must select the value
empirically in
empirically in the range [0, 100]

To save the parameters of the detection tooldetector, click the the Apply Image Modified button. To  To cancel the changes, click the Cancel Image Modified button.

Configuration of the Signal detector is complete.