To configure the Track masking detector, do the following:

  1. Create the required detector and specify its parameters (see Configuring detectors and their sub-detectors).
  2. Below the created detector, click Create…  Track masking.

By default, the detector is enabled and set to mask object tracks.

If necessary, you can change the detector parameters. The list of parameters is given in the table:

ParameterValueDescription
Object features
Record mask to archiveYesMask is recorded to the archive by default. To disable the parameter, select the No value
No
Other
EnableYesThe detector is enabled by default. To disable the detector, select the No value
No
NameTrack maskingEnter the detector name or leave the default name
Masking area height (%)100Specify the height of the mask as a percentage of its original size. The value must be in the range [100, 200]
Masking area width (%)100Specify the width of the mask as a percentage of its original size. The value must be in the range [100, 200]
TypeTrack maskingName of the detector type (non-editable field)

By default, the entire frame is the a detection area. In If necessary, in the preview window, you can specify the set one or more skip areas using the anchor points Image Removed (see see Configuring a skip area). Objects aren't masked in objects within these areas will not be masked.

Info
titleNote
  • For convenience of configuration, you can "freeze" the frame. Click the Image Modified button. To cancel the action, click this button again.
  • Detection area is displayed by default. To hide the detection area, click the Image Modified button. To cancel the action, click this button again.

To save the parameters of the detector, click the Apply button. To cancel the changes, click the Cancel Image Modified button.

Configuration of the Track masking is masking detector is complete.