Go to documentation repository
Documentation for Axxon One 2.0. Documentation for other versions of Axxon One is available too.
Attention!
Starting with DetectorPack 3.13, the People masking is no longer supported. We replaced it with the Track masking.
The Track masking allows you to hide objects in the video image:
- in real time;
- in the archive;
- during the search in the archive;
- when exporting from the archive.
Attention!
Objects are hidden in the video image only for users who have the View masked video parameter disabled in the role settings (see Roles).
To configure the Track masking detector, do the following:
- Create the required detector and specify its parameters (see Configuring detectors and their sub-detectors).
- Below the created detector, click Create… → Track masking.
By default, the detector is enabled and set to mask object tracks.
If necessary, you can change the detector parameters. The list of parameters is given in the table:
Parameter | Value | Description |
---|---|---|
Object features | ||
Record mask to archive | Yes | Mask is recorded to the archive by default. To disable the parameter, select the No value |
No | ||
Other | ||
Enable | Yes | The detector is enabled by default. To disable the detector, select the No value |
No | ||
Name | Track masking | Enter the detector name or leave the default name |
Masking area height (%) | 100 | Specify the height of the mask as a percentage of its original size. The value must be in the range [100, 200] |
Masking area width (%) | 100 | Specify the width of the mask as a percentage of its original size. The value must be in the range [100, 200] |
Type | Track masking | Name of the detector type (non-editable field) |
By default, the entire frame is a detection area. If necessary, in the preview window, you can set one or more skip areas (see Configuring a skip area)—objects within these areas will not be masked.
Note
- For convenience of configuration, you can "freeze" the frame. Click the button. To cancel the action, click this button again.
- Detection area is displayed by default. To hide the detection area, click the button. To cancel the action, click this button again.
To save the parameters of the detector, click the Apply button. To cancel the changes, click the Cancel button.
Configuration of the Track masking detector is complete.