Documentation for Axxon One 2.0. Documentation for other versions of Axxon One is available too.

Previous page Configuring the Close-standing people detector  Configuring the standard sub-detectors of the Human pose detector Next page

Attention!

Starting with DetectorPack 3.13, the People masking is no longer supported. We replaced it with the Track masking.

To create the People masking, do the following:

  1. Create the Human pose detector (see Configuring the Human pose detector).
  2. Below the Human pose detector, click Create…  People masking.

People masking doesn't generate events. It uses the metadata from the Human pose detector to mask people on the video image:

  • on live video;
  • in the archive;
  • when exporting from the archive.

Attention!

People masking works only for those users who have the View masked video parameter disabled in the role settings (see Roles).

If necessary, you can change the detector parameters. The list of parameters is given in the table:

ParameterValueDescription
Object features
Record mask to archiveYesMask is recorded to the archive by default. To disable the parameter, select the No value
No
Other
EnableYesThe detector is enabled by default. To disable the detector, select the No value
No
NamePeople maskingEnter the detector name or leave the default name
TypePeople maskingName of the detector type (non-editable field)

To save the parameters of the detector, click the Apply  button. To cancel the changes, click the Cancel  button.

Configuration of the People masking is complete.