Go to documentation repository
...
№ | Parameter | Method for setting the parameter value | Parameter description | Representation | Default value | Value range |
The Filters tab | ||||||
1 | The Identification number* | Automatically | Displays the identification number of the State statistics object in the system | Digits, letters, periods, hyphen, dash, and underscore | NA | Depends on the number of the State statistics objects in the system |
2 | The Name* | Enter the value in the field | Sets the name of the State statistics object in the system | Latin alphabet, Cyrillic, and service characters | State statistics | A line containing a sequence of any characters (letters, digits, service characters except > and < characters), case-insensitive. Number of characters—from 1 to 60 |
3 | The Disable | Set the checkbox | Disables the State statistics object in the system | Boolean type | Clear | Set—the State statistics object is disabled and isn't used Clear—the State statistics object is enabled and used |
4 | The Display | Select the value from the list | Sets the Display parent object for the given State statistics object | Names of the Display objects registered in the system | Name of the Display parent object | Depends on the number of the Display objects in the system |
The Position group | ||||||
5 | The X field | Enter the value in the field | Sets the X coordinate in the horizontal axis for the upper left corner of the State statistics window | % of the screen width | 44 | From 0 to M*100, where M is the number of the installed monitors |
The Y field | Enter the value in the field | Sets the Y coordinate in the vertical axis for the upper left corner of the State statistics window | % of the screen height | 44 | From 0 to M*100, where M is the number of the installed monitors | |
The W field | Enter the value in the field | Sets the width of the State statistics window | % of the screen width | 44 | From 0 to M*100, where M is the number of the installed monitors | |
The H field | Enter the value in the field | Sets the height of the State statistics window | % of the screen width | 44 | From 0 to M*100, where M is the number of the installed monitors | |
The button | Click the button | Opens the window for changing the size and position of the State statistics window | NA | NA | NA | |
The Allow moving | Set the checkbox | Allows moving the State statistics window using the mouse | Boolean type | Clear | Set—allow moving the State statistics window using the mouse Clear—disable moving the State statistics window using the mouse | |
The Monitor drop-down list | Select the value from the list | Determines the number of the monitor in the system for which the coordinates are specified | Numbers of the monitors in OS | 1 | From 1 to 16 | |
The Objectstable | ||||||
6 | The Type drop-down list | Select the value from the list | Sets the type of the objects whose events must be displayed in the State statistics window | Available object types | NA | Depends on the objects registered in the system. You can select only those object types that have the "INFORMATION" or "ALARM" value selected in the Processing messages column on the Events tab of the ddi.exe utility (see The Events tab) |
The Event type drop-down list | Select the value from the list | Sets the events that must be displayed in the State statistics window | Events available for the selected object | NA | Depends on the object type | |
The Color drop-down list | Select the value from the list | Sets the color of the state displayed in the table and on the graph in the State statisticswindow | Color palette | Black | RGB color | |
Out of the group | ||||||
7 | The Number of pixels field | Enter the value in the field | Sets the number of pixels to be displayed on the State statistics graph state statistics graph | Integer numbers | 0 | >=0 |
The DB tab
...